ELE15-03184
| Final | 10/5/2015 | 10/5/2015 | 10/5/2015 3:17:31 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer Needed temp service inspection
|
ELE15-03184
| Temporary Service | 10/5/2015 | 10/5/2015 | 10/5/2015 3:17:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer t/s u/g n ok
|
ELE15-03117
| Electrical Rough-In | 10/5/2015 | 10/5/2015 | 10/5/2015 2:51:18 PM | P | PASS |
|
|
Underground Inspection. contact is Chad VanOrden at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce Feeders and stubs through foundation rough in ok cover
|
ELE15-02908
| Electrical Rough-In | 10/5/2015 | 10/5/2015 | 10/5/2015 2:29:32 PM | P | PASS |
|
|
Concrete encased on wash building and patial underground. ###-#### Concrete encases electrode and underground north side from meter area to north corners of building rough in ok cover
|
ELE15-03189
| Final | 10/5/2015 | 10/5/2015 | 10/5/2015 2:09:03 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt Needed rough in permanent service.
|
ELE15-03189
| Rough-In Permanent Service | 10/5/2015 | 10/5/2015 | 10/5/2015 2:08:38 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt 210.52- Shall have a receptacle outlet with in 12' of previous measured along floor line. M. bed. 300.4- NM cable shall be protected from physical damage where ran through bored hole that does not maintain 1 1/4" from framing surface. 320.23(A)- Cables ran with in 7' of attic access shall be protected by guard strips.
|
ELE15-03176
| Final | 10/2/2015 | 10/5/2015 | 10/5/2015 1:15:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Amanda Payne Rough in and final ok on lights and outlets
|
ELE15-02881
| Rough-In Permanent Service | 10/5/2015 | 10/5/2015 | 10/5/2015 10:40:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Temp pole: 250 GFI breaker did not trip when tested. Posted notice. Rough in ok cover p/s u/g n ok
|
ELE15-02903
| Electrical Rough-In | 10/4/2015 | 10/5/2015 | 10/5/2015 9:57:57 AM | A | PASS |
|
|
Please inspect garage only for cover please Phone #: ###-#### Inspection requested via web by Robert Schroder Check for 30 amp rated disconnecting means as per 230.79. Garage only rough in ok cover
|
ELE15-02902
| Rough-In Permanent Service | 10/4/2015 | 10/5/2015 | 10/5/2015 9:55:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Schroder Check for 30 amp rating on garage disconnecting means. Rough in ok cover p/s u/g n ok
|
ELE15-03100
| Electrical Rough-In | 10/2/2015 | 10/5/2015 | 10/5/2015 9:24:13 AM | A | PASS |
|
|
Wall rough- in please Phone #: ###-#### Inspection requested via web by Celinda Winters Discussed showroom window receptacles, small windows on each side of doors only 31" wide so informed receptacles not needed for these small windows. Wall rough in ok cover
|
ELE15-03162
| Temporary Service | 10/2/2015 | 10/5/2015 | 10/5/2015 8:55:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
|
ELE15-03161
| Temporary Service | 10/2/2015 | 10/5/2015 | 10/5/2015 8:48:12 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson 250.24- A grounded service shall have a connection from the grounding electrode to the grounded conductor. Called contact to inform of correction, no answer and unable to leave message because mail box is full.
|
ELE15-02908
| Electrical Rough-In | 10/2/2015 | 10/5/2015 | 10/5/2015 8:16:20 AM | A | CANC |
|
|
We are requesting a partial underground inspection and a ufer inspection at the washing bldg. for Monday 10/5/15 in the AM. Our contact is Rod @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Needed PM inspection, rescheduled
|