Inspections for the day of: Monday, October 5, 2015.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-03184 Final10/5/201510/5/201510/5/2015 3:17:31 PMPCANC
Phone #: ###-#### Inspection requested via web by ron spen cer Needed temp service inspection
ELE15-03184 Temporary Service10/5/201510/5/201510/5/2015 3:17:18 PMPPASS
Phone #: ###-#### Inspection requested via web by ron spen cer
t/s u/g n ok
ELE15-03117 Electrical Rough-In10/5/201510/5/201510/5/2015 2:51:18 PMPPASS
Underground Inspection. contact is Chad VanOrden at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce Feeders and stubs through foundation rough in ok cover
ELE15-02908 Electrical Rough-In10/5/201510/5/201510/5/2015 2:29:32 PMPPASS
Concrete encased on wash building and patial underground. ###-#### Concrete encases electrode and underground north side from meter area to north corners of building rough in ok cover
ELE15-03189 Final10/5/201510/5/201510/5/2015 2:09:03 PMPCANC
Phone #: ###-#### Inspection requested via web by Greg Traudt Needed rough in permanent service.
ELE15-03189 Rough-In Permanent Service10/5/201510/5/201510/5/2015 2:08:38 PMPFAIL
Phone #: ###-#### Inspection requested via web by Greg Traudt 210.52- Shall have a receptacle outlet with in 12' of previous measured along floor line. M. bed. 300.4- NM cable shall be protected from physical damage where ran through bored hole that does not maintain 1 1/4" from framing surface.
320.23(A)- Cables ran with in 7' of attic access shall be protected by guard strips.
ELE15-03176 Final10/2/201510/5/201510/5/2015 1:15:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Amanda Payne Rough in and final ok on lights and outlets
ELE15-02881 Rough-In Permanent Service10/5/201510/5/201510/5/2015 10:40:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Temp pole: 250 GFI breaker did not trip when tested. Posted notice. Rough in ok cover p/s u/g n ok
ELE15-02903 Electrical Rough-In10/4/201510/5/201510/5/2015 9:57:57 AMAPASS
Please inspect garage only for cover please Phone #: ###-#### Inspection requested via web by Robert Schroder Check for 30 amp rated disconnecting means as per 230.79. Garage only rough in ok cover
ELE15-02902 Rough-In Permanent Service10/4/201510/5/201510/5/2015 9:55:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder Check for 30 amp rating on garage disconnecting means. Rough in ok cover p/s u/g n ok
ELE15-03100 Electrical Rough-In10/2/201510/5/201510/5/2015 9:24:13 AMAPASS
Wall rough- in please Phone #: ###-#### Inspection requested via web by Celinda Winters Discussed showroom window receptacles, small windows on each side of doors only 31" wide so informed receptacles not needed for these small windows. Wall rough in ok cover
ELE15-03162 Temporary Service10/2/201510/5/201510/5/2015 8:55:34 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE15-03161 Temporary Service10/2/201510/5/201510/5/2015 8:48:12 AMAFAIL
Phone #: ###-#### Inspection requested via web by David Nelson
250.24- A grounded service shall have a connection from the grounding electrode to the grounded conductor.
Called contact to inform of correction, no answer and unable to leave message because mail box is full.
ELE15-02908 Electrical Rough-In10/2/201510/5/201510/5/2015 8:16:20 AMACANC
We are requesting a partial underground inspection and a ufer inspection at the washing bldg. for Monday 10/5/15 in the AM. Our contact is Rod @ ###-####. Thank you,
Phone #: ###-#### Inspection requested via web by Clint Tate Needed PM inspection, rescheduled