Inspections for the day of: Monday, October 5, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02273 Permanent Service10/5/201510/5/201510/5/2015 2:00:19 PMPPASS
Jay Phone #: ###-#### need to verify grounding electrode conductor connections p/s o/h rec ok
ELE15-02273 Electrical Rough-In10/5/201510/5/201510/5/2015 1:58:14 PMPFAIL
Jay Phone #: ###-#### NEC 334.12(B)(4) NM cable shall be installed in wet locations
GCE15-00037 GCE-Final10/5/201510/5/201510/5/2015 12:55:01 PMPPASS
Brandon ###-#### final ok
ELE15-03174 Electrical Rough-In10/2/201510/5/201510/5/2015 10:44:51 AMAPASS
Bonding Inspection Phone #: ###-#### Inspection requested via web by Louis Keller rough-in ok cover pool bonding, 4 corner, wet-niche fixture, pool cover
ELE15-03040 Final10/4/201510/5/201510/5/2015 10:23:46 AMAPASS
gate by garage will be open and slider into patio room Phone #: ###-#### Inspection requested via web by Jesse Fuentes final ok
ELE15-03164 Temporary Service10/3/201510/5/201510/5/2015 10:04:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE15-03165 Temporary Service10/3/201510/5/201510/5/2015 10:04:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE15-02503 Final10/5/201510/5/201510/5/2015 10:00:14 AMAPASS
Garage code 2020E Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
ELE15-03136 Electrical Rough-In10/2/201510/5/201510/5/2015 9:52:31 AMAPASS
Cover Up Inspection Phone #: ###-#### Inspection requested via web by Louis Keller rough-in ok cover pool underground conduits
ELE15-02296 Final10/2/201510/5/201510/5/2015 9:34:38 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn Sub-panel requires separation of grounded and grounding conductors.
ELE15-03166 Temporary Service10/3/201510/5/201510/5/2015 9:05:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE15-02863 Final10/2/201510/5/201510/5/2015 8:50:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Fletcher final ok
ELE15-03157 Final10/1/201510/5/201510/5/2015 8:26:34 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Amanda Payne Inspection cancelled from web by: Amanda Payne