MEC16-04396
| Final | 10/5/2016 | 10/5/2016 | 10/5/2016 4:28:49 PM | P | PASS |
|
|
Please call Lars an hour before for project progress and access Phone #: ###-#### Inspection requested via web by Lars Fernandez
|
MEC16-04408
| Final | 10/5/2016 | 10/5/2016 | 10/5/2016 3:57:23 PM | P | FAIL |
|
|
Would like late PM and call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria - fuses for A/C are oversized
|
MEC16-03910
| Final | 10/5/2016 | 10/5/2016 | 10/5/2016 3:38:05 PM | P | FAIL |
|
|
Fuses are oversized for A/C
|
MEC16-02295
| Rough-in | 10/5/2016 | 10/5/2016 | 10/5/2016 3:19:49 PM | P | PART |
|
|
Partial rough-in cover, hard lids ; duct seal. Onsite contact: Trever Jensen. Phone #: ###-#### Inspection requested via web by Melissa Kaae - okay to cover bathroom ceilings
|
MEC16-03910
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 2:21:50 PM | P | NH |
|
|
###-#### Martin Phone #: ###-#### Inspection requested via web by Krista Boss - left a notice
|
MEC15-04453
| Pressure Test | 10/5/2016 | 10/5/2016 | 10/5/2016 2:12:20 PM | P | PASS |
|
|
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day - 20lb gas pass for piping to outdoor fire pits
|
MEC16-04400
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 1:52:58 PM | P | NR |
|
|
Please call Mike at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
|
MEC16-04400
| Pressure Test | 10/4/2016 | 10/5/2016 | 10/5/2016 1:52:46 PM | P | NR |
|
|
Please call Mike at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
|
MEC16-04355
| Final | 9/29/2016 | 10/5/2016 | 10/5/2016 1:45:34 PM | P | PASS |
|
|
EARLY PM IF POSSIBLE PLEASE INSTALLER: BRANDAN ###-#### THANK YOU Phone #: ###-#### Inspection requested via web by Dustin Rich
|
MEC16-04383
| Rough-in | 10/4/2016 | 10/5/2016 | 10/5/2016 12:42:05 PM | A | PASS |
|
|
Need to light test exhaust duct, will be ready by 9:00 Phone #: ###-#### Inspection requested via web by Drew Tverdy - light test pass
|
MEC16-04241
| Rough-in | 10/5/2016 | 10/5/2016 | 10/5/2016 12:28:37 PM | P | PASS |
|
|
Fireplace inspection Inspection requested via web by william kerwin
|
MEC16-01199
| Mec-Aging Inspection | 10/5/2016 | 10/5/2016 | 10/5/2016 11:25:46 AM | | CANC |
|
|
|
MEC16-04372
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 11:23:46 AM | A | PASS |
|
|
ROUGH IN AND FINAL ON DUCTWORK MODIFICATION.... Phone #: ###-#### Inspection requested via web by Andrea Creek
|
MEC15-02759
| Conference | 10/4/2016 | 10/5/2016 | 10/5/2016 11:06:08 AM | A | DONE |
|
|
Please contact Pat Nichols to discuss plan for VRT boiler flue issues. Phone #: ###-#### Inspection requested via web by Melissa Kaae - Met with RM and discussed venting. Need documentation from boiler manufacure's engineering department showing changes from original installation instructions
|
MEC16-03795
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 9:21:39 AM | A | PART |
|
|
Hood is good to go. Waiting for the balance report paperwork and I will email it out as soon as I receive it. The only thing not in is the mechanical access panel because I am still waiting for it to show up. 8;00 a.m. will be a good time. I will not be there but the contractor will be but please call with any questions. Phone #: ###-#### Inspection requested via web by Drew Tverdy - tempoarary occupancy okay. Still waiting on access door and air balance report
|
MEC16-02668
| Final | 10/5/2016 | 10/5/2016 | 10/5/2016 9:08:30 AM | P | CANC |
|
|
thank you Phone #: ###-#### >> Inspection requested via web by Dustin Rich Inspection cancelled from web by: Dustin Rich
|
MEC16-03171
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 9:04:12 AM | A | PASS |
|
|
Please Call Rich Beckstead Project Manager at ###-#### as the building is locked and will need to gain access Phone #: ###-#### Inspection requested via web by patrick graves
|
MEC16-04268
| Pressure Test | 10/4/2016 | 10/5/2016 | 10/5/2016 8:32:36 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer - Not installed per approved plans. Need to install per approved plans or resubmit new plans showing changes
|
MEC16-04268
| Rough-in | 10/4/2016 | 10/5/2016 | 10/5/2016 8:32:06 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer - Not installed per approved plans. Need to install per approved plans or resubmit new plans showing changes
|
MEC16-04111
| Final | 10/4/2016 | 10/5/2016 | 10/5/2016 8:12:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige
|