Inspections for the day of: Wednesday, October 5, 2016.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-02987 Final10/5/201610/5/201610/5/2016 4:22:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
MEC16-04308 Rough-in10/5/201610/5/201610/5/2016 3:39:16 PMPFAIL
Phone #: ###-#### Inspection requested via web by Jeremy lehosit
dryer vent needs to be in a 2x6 wall
MEC16-04308 Pressure Test10/5/201610/5/201610/5/2016 3:38:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Jeremy lehosit
20lb gas
MEC16-04384 Final10/3/201610/5/201610/5/2016 3:16:58 PMPPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 3:00 pm . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette
5lb flue
MEC16-04152 Pressure Test10/4/201610/5/201610/5/2016 3:04:04 PMPPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
60,20lb gas 5lb flue
MEC16-04313 Pressure Test10/4/201610/5/201610/5/2016 2:48:58 PMPCANC
Please call Dan at ###-#### with a 30 minute heads up arrival time. Phone #: ###-#### Inspection requested via web by David or K Cole
under 6' bubble test gas line
MEC16-02259 Final10/5/201610/5/201610/5/2016 2:31:22 PMPFAIL
Mark Phone #: ###-####
Armaflex needs uv protction, linestes need to be in a sleeve where they touch the ground, openings where they enter the building need to be sealed up,
bvent needs 1" clearence to combustibles
all vent piping needs to be fastened with 3 screws
2nd dairy condensate needs to be run
MEC16-03575 Rough-in10/5/201610/5/201610/5/2016 2:06:38 PMPFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
need approved manual j
MEC16-03575 Pressure Test10/5/201610/5/201610/5/2016 2:06:07 PMPPART
Phone #: ###-#### Inspection requested via web by Bryan Palmer
20lb gas pass

still need flues
MEC16-04413 Final10/4/201610/5/201610/5/2016 1:50:30 PMPPASS
Call Eric to coordinate @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
MEC16-04413 Pressure Test10/4/201610/5/201610/5/2016 1:50:15 PMPCANC
Call Eric to coordinate @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
in garage no test witness needed
MEC16-04412 Final10/4/201610/5/201610/5/2016 1:49:42 PMPPASS
Call Eric to coordinate @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
MEC16-04389 Final10/5/201610/5/201610/5/2016 1:12:40 PMPNH
Early PM and a call when no way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC16-04329 Pressure Test10/5/201610/5/201610/5/2016 11:35:44 AMPPASS
PRESSURE TEST ON GAS LINE OUTSIDE. Phone #: ###-#### Inspection requested via web by Chris Field
MEC16-04329 Final10/5/201610/5/201610/5/2016 11:35:29 AMPPASS
PRESSURE TEST ON GAS LINE OUTSIDE. Phone #: ###-#### Inspection requested via web by Chris Field
MEC16-03241 Final10/4/201610/5/201610/5/2016 11:33:07 AMAFAIL
Phone #: ###-#### Inspection requested via web by Krista Boss
fresh air in garage needs to be insulated,
bvent needs 1" clearance to combustibles
MEC16-04329 Pressure Test10/3/201610/5/201610/5/2016 10:40:27 AMAPASS
PRESSURE TEST NEW GAS LINE Phone #: ###-#### Inspection requested via web by Chris Field
20lb gas
MEC16-03575 Pressure Test10/4/201610/5/201610/5/2016 10:24:22 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
all 3 gages at zero
MEC16-03575 Rough-in10/4/201610/5/201610/5/2016 10:23:50 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
need approved manual j on site for inspection
MEC16-04402 Final10/4/201610/5/201610/5/2016 10:02:52 AMAPASS
After 9:30 please.
Please contact Diane for access ###-####.
Contact Ryan with questions ###-####. Phone #: ###-#### Inspection requested via web by Lea Briggs
MEC16-04395 Rough-in10/4/201610/5/201610/5/2016 9:50:35 AMAFAIL
ceiling inspection Phone #: ###-#### Inspection requested via web by Tim Petsche
slock connection needs to be sealed, pipe runs need to be sealed better
MEC16-03204 Final10/4/201610/5/201610/5/2016 9:17:44 AMAPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
MEC16-00786 Rough-in10/4/201610/5/201610/5/2016 9:14:42 AMAPASS
Will Phone #: ###-####
MEC16-00786 Final10/5/201610/5/201610/5/2016 9:04:46 AMPPASS
Will Phone #: ###-####
MEC16-01207 Mec-Aging Inspection10/5/201610/5/201610/5/2016 8:06:23 AM PEND
MEC16-01186 Mec-Aging Inspection10/5/201610/5/201610/5/2016 8:03:54 AM PEND
MEC15-05667 Mec-Aging Inspection10/5/201610/5/201610/5/2016 8:02:41 AM CANC
MEC15-05667 DOC - Permit Expired10/5/201610/5/201610/5/2016 8:02:21 AMPPASS