MEC97-02742
| INSP - Gas log/ Fireplace | 10/3/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | A | CANC |
|
|
GIVEN TO ALLEN
|
BLD97-02090
| INSP - Energy code compliance | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | A | PASS |
|
|
|
BLD97-02452
| INSP - Final | 10/3/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | A | PASS |
|
|
9 AM
|
BLD97-02601
| INSP - Footings | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | A | NR |
|
|
STILL PLACING REBAR
|
BLD97-02212
| INSP - Footings | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PART |
|
|
PLAN SHOWS A KEYWAY IN GARAGE FTG....ASKED BLDR TO RESPOND AS IT IS NOT INSTALLED.
|
BLD97-02452
| INSP - Letter of compliance | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
C/C ISSUED
|
BLD97-02601
| INSP - Footings | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
SAYS TO REMIND YOU OF 1:30 APT. C/N POSTED AND ISSUES ANSWERED
|
BLD97-02104
| INSP - Conference | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | FAIL |
|
|
STEED PROJECT MGR STATED THIS WAS A V-1HR BLDG WITH SPRINKLER SUBSTITUTION...? THEY WERE NOT READY FOR A FRAME INSP AND HAVE NUMEROUS PENETRATIONS IN A VN BLDG
|
BLD97-02104
| INSP - Framing/Rough-in | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | NR |
|
|
NUMEROUS PENETRATIONS IN 1 HR CORRIDOR MEMBRANE WITH ROCKED COLUMNS, DUCT PENETRATIONS IN CEILING, CEILING NOT FRAMED COMPLETELY, NEED DETAILS FROM ARCHITECT FOR FIXES, VN BLDG
|
BLD96-01219
| INSP - Energy code compliance | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
|
BLD96-01219
| INSP - Framing/Rough-in | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
ALREADY COVERING LID AS PER C/N OK
|
BLD97-01349
| INSP - Conference | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
WANTS TO USE WHITE VAPOR BARRIER IN UNFINISHED SPACE, TYP
|
BLD97-01349
| INSP - Energy code compliance | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
|
BLD97-01545
| INSP - Conference | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
MET W/TERRY RECORDS AND SUPER ON SITE
|
BLD97-01545
| INSP - Site Preparation | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
2:30 APT. YOU MADE WITH HIM??????
|
BLD97-01828
| INSP - Foundation | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
LAST SECTION OF FDN WALL POURED
|
BLD97-01828
| INSP - Foundation | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | NR |
|
|
NEEDS 25" SPLICE ON REBAR LAPS....PLACING ADD BAR
|
BLD97-01828
| INSP - Footings | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | NR |
|
|
IMBEDDED WOOD IN FTG NORTH SIDE...DO NOT BACKFILL UNTIL REMOVED AND APPROVAL BY INSPECTOR
|
BLD97-02090
| INSP - Conference | 10/6/1997 | 10/6/1997 | 10/6/1997 12:00:00 AM | P | PASS |
|
|
COMING DOWN TO SPLIT OUT DUPLEX INTO TOWNHOUSE PERMITS
|
BLD97-02212
| INSP - Footings | 10/3/1997 | 10/6/1997 | 10/2/1997 12:00:00 AM | A | CANC |
|
|
CHANGED TO PM
|