Inspections for the day of: Friday, October 6, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03813 ELE-Aging Inspection10/6/200610/6/200610/12/2006 4:15:57 PM PASS
ELE06-03710 Electrical Rough-In10/6/200610/6/200610/6/2006 4:45:42 PMPFAIL
ted; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. COW
room count off and wires air lifted to sub panel
ELE06-03553 Electrical Rough-In10/6/200610/6/200610/6/2006 4:00:13 PMPPASS
Bob Schroder; Phone #: ###-#### Internet Inspection Request from: Julie Schroder
ELE06-03553 Permanent Service10/6/200610/6/200610/6/2006 4:00:04 PMPPASS
Bob Schroder; Phone #: ###-#### Internet Inspection Request from: Julie Schroder
P/S U/G N Ok
ELE06-02946 Permanent Service10/6/200610/6/200610/6/2006 3:42:01 PMPPART
inspection later afernoon for rehook of power alt contact at Mike ###-#### Internet Inspection Request from: Don Lustig
P/S O/H R Ok to connect power
has ground rod check water later.
ELE06-03259 Electrical Rough-In10/6/200610/6/200610/6/2006 2:43:12 PMPFAIL
joe - ###-#### cell; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
add outlets 3rd and 1st floors
install boxes for light fixture 3rd floor
angle connector not permitted to be conceiled
acorn connectors improperly used
nail plates and parallel protectikon several places
damaged outer sheath on feeder cable
feeder cable shall be connected to service panel
ELE05-04587 Final10/6/200610/6/200610/6/2006 2:35:23 PMPPASS
ELE06-03542 Electrical Rough-In10/6/200610/6/200610/6/2006 1:54:46 PMPPART
in need of inspection of trench,from house to unattach garage. thank you! ; Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
Trench,from house to unattach garage ok
ELE06-03212 Electrical Rough-In10/6/200610/6/200610/6/2006 12:49:43 PMPPASS
pat Note: please call 1/2 hr prior; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
r/i ok except party wall
ELE06-03031 Conference10/6/200610/6/200610/6/2006 11:13:27 AMAPART
Scheduled by a contractor via Hello! on 10/6/2006 at 7:28:49 AM. Contact: ###-####.
talked about ceilings
ELE06-02915 Final10/5/200610/6/200610/6/2006 11:01:22 AMAPASS
susan ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE06-02369 Final10/5/200610/6/200610/6/2006 10:36:43 AMPCANC
Internet Inspection Request from: Steve Craig
ELE06-02369 Final10/5/200610/6/200610/6/2006 10:34:38 AMAFAIL
Internet Inspection Request from: Steve Craig
island counter recep above counter and protect romex in microwave space
\GFCI recep within 6 ft of laundry sink
secure box on hydronic system
secure permit for outside lighting
ELE06-03149 Electrical Rough-In10/5/200610/6/200610/6/2006 9:36:44 AMAPASS
joe; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
7th floor ceiling ok
ELE06-02767 Final10/5/200610/6/200610/6/2006 8:51:25 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE06-03702 Rough-In Permanent Service10/6/200610/6/200610/6/2006 8:32:25 AMAPASS
###-#### FROM STATE GO TO 31ST, GO SOUTH TO END OF STREET TURN EAST. HOUSE ON LEFT 1/2 WAY DOWN BLOCK. GARAGE IS IN THE BACK OF PROPERTY. ANY ? CALL BILL@###-#### THANK YOU. Internet Inspection Request from: Bob Glenn
R/I Ok
P/S O/H N Ok