Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-02966 Plumbing Rough-in10/5/201510/6/201510/6/2015 3:46:54 PMPPASS
JOB # 13313. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-03399 Plumbing Rough-in10/6/201510/6/201510/6/2015 3:21:34 PMPPASS
Phone #: ###-#### Inspection requested via web by Aarin Van Curen
>add screws to t/s unit when pulling test
PLM15-03421 Plumbing Rough-in10/5/201510/6/201510/6/2015 2:52:36 PMPFAIL
JOB # 18224. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>re-test on dwv right side failed @ 0psi
PLM15-03434 Water and/or Sewer10/5/201510/6/201510/6/2015 2:27:18 PMPCANC
Sewer Inspection Phone #: ###-#### Inspection requested via web by Dan Bastian
PLM15-02821 Final10/6/201510/6/201510/6/2015 2:26:01 PMPFAIL
TENANT IMPROVEMENT FINAL TRIM Phone #: ###-#### Inspection requested via web by Chris Field
>caulk around mop sink
>add temp limiting device that is ASSE 1070 certified on both lavs to limit hot water to 120 degrees or less. per 413.1 upc
PLM15-03446 DOC - Permit Finaled10/6/201510/6/201510/6/2015 1:54:12 PMPPASS
PLM15-03446 Water and/or Sewer10/6/201510/6/201510/6/2015 1:54:02 PMPPASS
Phill Phone #: ###-####
>w/s ok
>no sprinkler tee installed at time of inspection
PLM15-03441 Groundwork10/5/201510/6/201510/6/2015 1:34:49 PMPFAIL
ground work - run water/sewer underneath slab. call Don Beevers when en route at ###-#### Phone #: ###-#### Inspection requested via web by TERRY SIDWELL
>need cleanout at upper terminal, 3"
PLM15-02609 Plumbing Rough-in10/6/201510/6/201510/6/2015 1:09:24 PMPPASS
its ready now. Phone #: ###-####
>radiant tube ok 100# test/180f pipe
PLM15-02787 Final10/5/201510/6/201510/6/2015 11:48:35 AMAPASS
House is open Phone #: ###-#### Inspection requested via web by Janene/ Dan
PLM15-03180 Groundwork10/5/201510/6/201510/6/2015 11:33:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige
PLM15-02691 Water and/or Sewer10/5/201510/6/201510/6/2015 11:21:28 AMACANC
Call 30 minutes ahead. Phone #: ###-#### Inspection requested via web by Todd Walter
PLM15-02691 Plumbing Rough-in10/6/201510/6/201510/6/2015 11:20:08 AMPPASS
Call 30 minutes ahead. Phone #: ###-#### Inspection requested via web by Todd Walter
>gas to dryer ok, 20# test
PLM15-03444 Water and/or Sewer10/6/201510/6/201510/6/2015 10:58:36 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Darren Wood Inspection cancelled from web by: Darren Wood
PLM15-03434 Water and/or Sewer10/5/201510/6/201510/6/2015 10:22:06 AMAPART
Sewer Inspection Phone #: ###-#### Inspection requested via web by Dan Bastian
>visual on 6" east trunk line @ 1.8% grade, ok
PLM15-01809 Final10/5/201510/6/201510/6/2015 9:59:53 AMAFAIL
Inspector
Plz Call me for entry details Phone #: ###-#### Inspection requested via web by Scott Myers
>install pan with drain under water heater(508.4 ispc)
>use approved material on t&p, pvc is not approved, and turn down 90 outside.(608.5 ispc)
PLM15-03414 Water Heater Final10/5/201510/6/201510/6/2015 9:21:52 AMAPASS
Main contact will be Teresa Hugl please call her prior to arrival at ###-####. Plumber was Andrew P please call him should you have any questions at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Guzman
PLM15-02553 Final10/6/201510/6/201510/6/2015 9:07:05 AMAFAIL
5151 code Phone #: ###-#### Inspection requested via web by Robert Madrigal
>sprinkler backflow needs permitted, certified, partially uncovered and inspected before plumbing can be finaled.
PLM15-03444 Water and/or Sewer10/5/201510/6/201510/6/2015 8:31:36 AMANR
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM15-02821 Final10/6/201510/6/201510/6/2015 12:00:00 AMPFAIL
TENANT IMPROVEMENT FINAL TRIM Phone #: ###-#### Inspection requested via web by Chris Field
>caulk around mop sink
>add temp limiting device that is ASSE 1070 certified on both lavs to limit hot water to 120 degrees or less. per 413.1 upc