Inspections for the day of: Tuesday, October 6, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02422 Final10/6/201510/6/201510/6/2015 3:37:25 PMPPASS
Please contact James ###-#### with any questions Phone #: ###-#### Inspection requested via web by Tracy Robertson range and dryer not set or on site final ok
ELE15-02606 Permanent Service10/6/201510/6/201510/6/2015 2:19:33 PMPPASS
Mitch Phone #: ###-#### p/s u/g rec ok
ELE15-02607 Permanent Service10/6/201510/6/201510/6/2015 2:18:59 PMPPASS
Mitch Phone #: ###-#### p/s u/g rec ok
ELE15-02460 Electrical Rough-In10/5/201510/6/201510/6/2015 1:45:47 PMPPASS
Greg Milburn is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce 2nd floor walls only rough-in ok cover
ELE15-00948 Electrical Rough-In10/5/201510/6/201510/6/2015 1:24:53 PMPPASS
call home owner Roger before arrival ###-####
Rough-in on upstairs
Phone #: ###-#### Inspection requested via web by danny perrine upstairs addition ok cover
ELE15-03190 Electrical Rough-In10/6/201510/6/201510/6/2015 12:58:21 PMPPASS
Phone #: ###-#### light swithes and outlets ok cover
ELE15-03217 Electrical Rough-In10/6/201510/6/201510/6/2015 12:47:55 PMPFAIL
John is currently out of town. Please call general contractor Tim if any issues

Rough in only of residence Meter will be set on garage at a later date.


Phone #: ###-#### Inspection requested via web by John Harvey 210.52 (2) wall space greater then 24" requires a receptacle aswell as master bed entry if a hall longer then 10' requires a receptacle 334.30 NM cable shall be supported with 12" of a box and shall not be stapled on edge
ELE15-03191 Conference10/5/201510/6/201510/6/2015 12:03:57 PMADONE
Rhonda Phone #: ###-#### conference on outlet placement and service to dog grooming areas and gfci protection
ELE15-03194 Temporary Service10/5/201510/6/201510/6/2015 11:19:36 AMAPASS
Mark Phone #: ###-#### t/s o/h n ok
ELE15-02539 Final10/5/201510/6/201510/6/2015 11:03:45 AMAFAIL
Phone #: ###-#### Inspection requested via web by kendall bender 406.4 (b) receptacles in laundry reading open ground
ELE15-00181 Electrical Rough-In10/5/201510/6/201510/6/2015 10:45:02 AMAPASS
Underground electrical conduit for 120 volt hot tub and landscape post from main panel in rear of house to front yard street side of swimming pool. GFCI protected circuit. Phone #: ###-#### Inspection requested via web by Heath Thomas underground for bbq and for hot tub ok cover
ELE15-03185 Final10/5/201510/6/201510/6/2015 10:19:54 AMACANC
Temp pole Phone #: ###-#### Inspection requested via web by Greg Idsinga contractor will either move temp or energize existing service
ELE15-03145 Electrical Rough-In10/5/201510/6/201510/6/2015 9:45:06 AMAPASS
Please call Louis about the equal potential bonding grid at ###-####. Phone #: ###-#### Inspection requested via web by Louis Keller equipotential pool bonding ok cover
ELE15-01028 Final10/5/201510/6/201510/6/2015 9:21:00 AMAPASS
Dave is on site at 7am this morning to fix the outlet problem. Phone #: ###-#### Inspection requested via web by Don Lustig corrections fixed final ok
ELE15-01981 Final10/5/201510/6/201510/6/2015 9:03:27 AMAFAIL
Call for access instructions. Phone #: ###-#### Inspection requested via web by Kendra Lanham 210.8 all receptacles serving counter top and islands in a kitchen shall have GFCI & all 120v receptacles ina garage shall be GFCI 440.4 (c) OCPD shall be sized in accordance with nameplate ratings
ELE15-03202 Electrical Rough-In10/5/201510/6/201510/6/2015 8:35:57 AMACANC
call ###-#### for access Phone #: ###-#### Inspection requested via web by David Nelson no access called contact voice mailbox is full could not leave message