Inspections for the day of: Friday, October 6, 2017.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02418 ELE-Aging Inspection10/6/201710/6/201710/6/2017 2:42:29 PM FAIL
contractor has not scheduled further inspections for any work done...contractor must verify if work completed or no other work performed under this permit
ELE13-03198 ELE-Aging Inspection10/6/201710/6/201710/6/2017 2:34:22 PM FAIL
waiting on contractor to schedule needed final inspection and get access
ELE17-02453 Electrical Rough-In10/4/201710/6/201710/6/2017 2:32:35 PMPPASS
Above grid inspection Phone #: ###-#### Inspection requested via web by Zane Robertson..grid ok to cover
ELE17-02472 Electrical Rough-In10/4/201710/6/201710/6/2017 2:32:07 PMPPASS
Above grid inspection Phone #: ###-#### Inspection requested via web by Zane Robertson..grid ok to cover
ELE17-00811 Electrical Rough-In10/4/201710/6/201710/6/2017 2:31:39 PMPPASS
Above grid inspection Phone #: ###-#### Inspection requested via web by Zane Robertson... ok to cover
ELE17-02502 Final10/6/201710/6/201710/6/2017 2:30:31 PMPNR
FINAL ON 3 SETS PAN CHANNEL LETTERS Phone #: ###-#### Inspection requested via web by Dana Vance...not ready for final...changed to rough inspection
ELE17-02502 Electrical Rough-In10/6/201710/6/201710/6/2017 2:29:22 PMPPASS
FINAL ON 3 SETS PAN CHANNEL LETTERS Phone #: ###-#### Inspection requested via web by Dana Vance...UL listed sign and driver, disconnect on driver installed on rough, readily accesssible
ELE17-02735 Final10/6/201710/6/201710/6/2017 1:29:45 PMPPASS
Phone #: ###-#### Inspection requested via web by Stephanie Huston..
corrections made...ok to final
ELE17-02659 Final10/5/201710/6/201710/6/2017 12:34:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Christy Cheney...job complete, verified labelling and power reconnect, ok to final
ELE13-02826 Final10/6/201710/6/201710/6/2017 11:59:11 AMPPASS
UL Label on top of letters. I have photos Phone #: ###-#### Inspection requested via web by Steve VanWinkle...job complete...ul listing from contractor...ok to final
ELE16-04166 Final10/3/201710/6/201710/6/2017 11:33:19 AMAPASS
Owner will be there all day Phone #: ###-#### Inspection requested via web by Craig Korell..ok to final
ELE17-03248 Electrical Rough-In10/5/201710/6/201710/6/2017 11:06:39 AMAPASS
Inspect to cover 90 feet of underground piping from new IPCO pole to Suez water vault service stub up. Phone #: ###-#### Inspection requested via web by Jeremy Cloud...ok to cover
ELE17-02649 Electrical Rough-In10/5/201710/6/201710/6/2017 11:06:07 AMAPASS
Underground inspection - contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell...ok to cover..underground from transformer and lights in nurses station drop ceiling
ELE17-03366 Electrical Rough-In10/6/201710/6/201710/6/2017 10:44:05 AMAPASS
Call James ###-#### with any questions Phone #: ###-#### Inspection requested via web by William Salts...rough ok for building..all lights UL listed and lamps...second rough will be called in for portamache
ELE17-02789 Electrical Rough-In10/5/201710/6/201710/6/2017 10:13:48 AMAPASS
We are requesting an underground inspection for tomorrow morning. Our contact is Bryant @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate...3 feeder pipes...east side of complex...ok to cover
ELE17-02761 Final10/3/201710/6/201710/6/2017 9:58:20 AMAFAIL
Please call Mr Harris when you are on the way 179468 Phone #: ###-#### Inspection requested via web by Louis Keller...

all metal parts within 5' of tub shall be bonded to tub....lights within 5' of hot tub shall be GFI protected and above 5' of waterline 680.22(B)3
ELE17-03374 Electrical Rough-In10/5/201710/6/201710/6/2017 9:23:02 AMAPASS
Partial underground for (2) pool lights ; (1) spa light. Bonding for (4) EQ corners, (1) Steel/equipment, (2) autocover Phone #: ###-#### Inspection requested via web by Lars Johnson...ok to cover bonding and pipe stubs for lights at pool and spa
ELE17-02681 Final10/5/201710/6/201710/6/2017 9:14:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
ELE17-03317 Electrical Rough-In10/5/201710/6/201710/6/2017 8:33:23 AMAPASS
Kitchen remodel Phone #: ###-#### Inspection requested via web by David McClellan..ok to cover...not requiring outlets be cut in counter next to sink...existing outlets will cover requirement for 2' within sink...oulet on wall less than 5' high will cover for wallspacing in dining room
ELE17-03372 Temporary Service10/5/201710/6/201710/6/2017 8:06:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Murray...t/s u/g new ok
ELE17-03248 Electrical Rough-In10/5/201710/6/201710/5/2017 3:20:45 PMACANC
Need to inspect 90'' of 2" underground piping from IPCO pole to vault. Phone #: ###-#### >> Inspection requested via web by Jeremy Cloud Inspection cancelled from web by: Jeremy Cloud
ELE17-03359 Final10/5/201710/6/201710/5/2017 3:01:53 PMAPASS
Please call for access to home. Phone #: ###-#### Inspection requested via web by Jose Guerrero....job complete ok to final
ELE17-02659 Final10/5/201710/6/201710/5/2017 12:48:29 PMPCANC
scheduled wrong day
ELE17-02690 Final10/5/201710/6/201710/5/2017 12:45:14 PMAPASS
Phone #: ###-#### Inspection requested via web by Christy Cheney...job complete...ok to final