MEC19-04309
| Final | 9/30/2019 | 10/7/2019 | 10/7/2019 2:42:13 PM | P | FAIL |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- mini split ok- need electrical permit issued for disconnect installed for condenser to final out
|
MEC19-04377
| Final | 10/2/2019 | 10/7/2019 | 10/7/2019 2:26:29 PM | P | PASS |
|
|
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- furnace a/c coil co ok
|
MEC19-04461
| Final | 10/7/2019 | 10/7/2019 | 10/7/2019 2:02:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- furnace only co ok
|
MEC19-04464
| Rough-in | 10/7/2019 | 10/7/2019 | 10/7/2019 1:27:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE 1- need approved man j onsite with right company and equipment on it 2- need to seal all boots that were missed 3- b vent for water heater insulation shield needs 1" clearance to shield 4- combustion air needs installed per IECC R402.4.4 furnace is in closet- will require all metal insulated or communicate 1 high 1 low with house conditioned space
left notoce front window
|
MEC19-04464
| Pressure Test | 10/7/2019 | 10/7/2019 | 10/7/2019 1:22:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass- tagged meter location
|
MEC19-04369
| Final | 10/2/2019 | 10/7/2019 | 10/7/2019 11:48:21 AM | P | CANC |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|
MEC19-03233
| Final | 10/4/2019 | 10/7/2019 | 10/7/2019 11:25:58 AM | A | PASS |
|
|
GARI ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok
|
MEC19-03054
| Final | 10/7/2019 | 10/7/2019 | 10/7/2019 11:25:37 AM | A | PASS |
|
|
fireplace final ok
|
MEC19-04391
| Rough-in | 10/4/2019 | 10/7/2019 | 10/7/2019 11:10:10 AM | A | FAIL |
|
|
Please call Ryan with any questions or concerns at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum 1- need to resubmit man j for the way ducting is ran now or run per approved man j- supply and R/A duct missing or ran different 2- is W/H flue solid core pvc for tanlless water heater can not see labeling on PVC? needs vent thru roof to maintain 10' from property line and maintain 10' or 3' from outside air intake
left notice YMC folder
|
MEC19-04391
| Pressure Test | 10/7/2019 | 10/7/2019 | 10/7/2019 11:06:56 AM | A | PASS |
|
|
Please call Ryan with any questions or concerns at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- 20 lb gas pass- tagged meter location
|
MEC19-04114
| Final | 10/2/2019 | 10/7/2019 | 10/7/2019 9:33:28 AM | A | PASS |
|
|
please call our lead installer Brad 30-45 mins before arrival so we can have flue under pressure when you arrive. Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co ok- 5lb flue test pass
|
MEC19-04380
| Final | 10/4/2019 | 10/7/2019 | 10/7/2019 8:55:38 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- need approved weather tight connector on one of MC cables outside at condenser- need to seal both raceway weather tight- need electrical permit issued for new mini split system
|
MEC19-02784
| Final | 10/4/2019 | 10/7/2019 | 10/7/2019 8:13:24 AM | A | PASS |
|
|
as early as possible . Inspection requested via web by Don Dowers- final ok
|
MEC18-03615
| Mec-Aging Inspection | 10/7/2019 | 10/7/2019 | 10/7/2019 8:01:33 AM | | FAIL |
|
|
needs called in for inspection or request extension- bld still open-
|
MEC19-00982
| Mec-Aging Inspection | 10/7/2019 | 10/7/2019 | 10/7/2019 8:00:26 AM | | CANC |
|
|
|
MEC19-00982
| Final | 10/7/2019 | 10/7/2019 | 10/7/2019 8:00:09 AM | A | PASS |
|
|
should have finaled on R/I inspection
|
MEC19-00979
| Mec-Aging Inspection | 10/7/2019 | 10/7/2019 | 10/7/2019 7:59:12 AM | | FAIL |
|
|
contractor needs to schedule inspection if works complete- permit will expire next aging if no activity
|
MEC19-04212
| Final | 10/4/2019 | 10/7/2019 | 10/4/2019 3:33:14 PM | A | PASS |
|
|
Please call homeowner on your way at ###-#### Phone #: ###-#### Inspection requested via web by Debbie Marino
|
MEC19-04212
| Pressure Test | 10/4/2019 | 10/7/2019 | 10/4/2019 3:32:24 PM | A | PASS |
|
|
Please call homeowner on your way at ###-#### Phone #: ###-#### Inspection requested via web by Debbie Marino- 20lb gas pass
|