Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD99-02530 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMAPART
tom ###-#### exterior nailing insp 407 area/ ext nailing and HD's ok ; c/n for clarification of truss substituted for beams
BLD99-01882 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMAPART
BILL-- 59-9616---REBAR REPLACEMENT not fram, ext. masonry walls… pend. Spec. insp.
MIS99-00182 BLD-Final10/7/199910/8/199910/8/1999 12:00:00 AMAPASS
Martin ###-#### l/c issued … m.h. sit up in park
BLD98-03861 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMAPART
LARRY CELL-- ###-#### FR--CEILING w.I.p. grid ok pend elec r/I
BLD99-02122 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMAFAIL
mike-- ###-#### shear wall insp ext. nailing ok ; c/n : hold downs not as shown retro fit equiv. Bolts. 407 area
MEC99-02139 Final10/7/199910/8/199910/8/1999 12:00:00 AMAPASS
Steven ###-####
MEC99-00988 Final10/7/199910/8/199910/8/1999 12:00:00 AMAFAIL
###-####-gregory//fn left c/n
MIS99-00163 BLD-Final10/7/199910/8/199910/8/1999 12:00:00 AMAFAIL
This is the former "pink house" - if any questions, please call Bob @ ###-#### then #1336 c/n : ground not level ( big hole )
BLD99-02852 BLD-Foundation10/8/199910/8/199910/8/1999 12:00:00 AMPCANC
JOAN--- ###-#### FOUND INSP--CALL 1ST BEFORE INSP
BLD99-02097 BLD-Footing10/8/199910/8/199910/8/1999 12:00:00 AMPPART
LEWIS ###-#### FOR FT INSP ftg ok recall for wall and steel
MEC98-00576 Final10/8/199910/8/199910/8/1999 12:00:00 AMPPASS
after 4pm please call first ###-####
BLD98-00407 BLD-Framing/Rough-in10/8/199910/8/199910/8/1999 12:00:00 AMPPART
floor ###-####after 4pm must call first ok to cover floor
BLD98-01448 BLD-Framing/Rough-in10/8/199910/8/199910/8/1999 12:00:00 AMPPART
2ND FLOOR- CEILING GRID INSP & 1ST FL EAST WEST ENTRIES ---J.C. ###-#### FR INS need verify damper listing ok to tile pending manuf's instruction
BLD99-01996 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMPFAIL
Alan ###-#### keep c/n ; ok to insu. Homeowner
BLD99-02842 BLD-Foundation10/7/199910/8/199910/8/1999 12:00:00 AMPPASS
before 4pm Steve ###-####
BLD99-02971 BLD-Other10/7/199910/8/199910/8/1999 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 10/07/1999 at 11:46:14. Contact: ###-####. Pool grid ok to gunite
BLD99-01963 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMPPART
SAM--- ###-#### --CEILIING INSP OK TO COVER
BLD99-02554 BLD-Framing/Rough-in10/7/199910/8/199910/8/1999 12:00:00 AMPPART
KAINOA--- ###-#### R/I INSP shaft; one side ok modify to T 7 B , ubc for construction