ELE12-00708
| ELE-Aging Inspection | 10/8/2013 | 10/8/2013 | 10/9/2013 3:58:15 PM | | DONE |
|
|
Waiting on owner
|
ELE09-02411
| ELE-Aging Inspection | 10/8/2013 | 10/8/2013 | 10/8/2013 4:58:12 PM | | DONE |
|
|
Still under construction
|
ELE13-02793
| Rough-In Permanent Service | 10/8/2013 | 10/8/2013 | 10/8/2013 4:44:19 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey 300.4 Bored holes less than 1 1/4" from stud surface shall be protected from physical damage. NM cable and low volt shall be protected. 210.52- Receptical outlets shall be installed so that no point measured along floor line is more than 6' from outlet. Master bed and family rm. 210.52- Receptical outlet shall be installed with in 6' of door opening measured along floor line. Down bed pocket door to bath. * Out patio ceilings covered prior to inspection.
|
ELE13-02578
| Electrical Rough-In | 10/8/2013 | 10/8/2013 | 10/8/2013 3:25:02 PM | P | PASS |
|
|
wall cover. Danny on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen 12th floor unit 1200 wall rough in ok cover
|
ELE13-01908
| Final | 10/8/2013 | 10/8/2013 | 10/8/2013 2:39:41 PM | P | PASS |
|
|
House is open Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
|
ELE13-02548
| Final | 10/7/2013 | 10/8/2013 | 10/8/2013 2:18:24 PM | A | NH |
|
|
Call Evan at ###-#### he will let you into the house. Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser Called contact and left 2 messages. Contractor to reschedule
|
ELE13-02023
| Permanent Service | 10/7/2013 | 10/8/2013 | 10/8/2013 1:48:32 PM | P | PASS |
|
|
Phone #: 2089546718 >> Inspection requested via mobile web by david luke p/s o/h n ok
|
ELE13-02023
| Permanent Service | 10/7/2013 | 10/8/2013 | 10/8/2013 1:11:30 PM | P | PASS |
|
|
Phone #: 2089546718 >> Inspection requested via mobile web by david luke p/s u/g n ok
|
ELE13-02189
| Final | 10/8/2013 | 10/8/2013 | 10/8/2013 12:38:23 PM | P | FAIL |
|
|
call first Phone #: ###-#### >> Inspection requested via web by PAT MILLER 210.52- Receptical outlet shall be installed at the end of peninsula. 422.30- A disconnecting means shall be provided to diconnect all ungrounded conductors. Built in oven
|
ELE13-02510
| Electrical Rough-In | 10/8/2013 | 10/8/2013 | 10/8/2013 12:21:25 PM | P | PASS |
|
|
Inspection for back entry Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Back entry ceiling and out lights rough in ok cover
|
ELE13-01617
| Permanent Service | 10/7/2013 | 10/8/2013 | 10/8/2013 12:09:32 PM | A | PASS |
|
|
don Phone #: ###-#### p/s o/h n ok
|
ELE13-02778
| Rough-In Permanent Service | 10/7/2013 | 10/8/2013 | 10/8/2013 10:43:48 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman rough in ok cover p/s o/h n ok
|
ELE13-02095
| Final | 10/7/2013 | 10/8/2013 | 10/8/2013 10:23:38 AM | A | PASS |
|
|
Please call Dianne (###-####) 30min ahead. Phone #: ###-#### >> Inspection requested via web by Brad Girard Final ok
|
ELE13-02509
| Final | 10/7/2013 | 10/8/2013 | 10/8/2013 10:06:34 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by David Nelson final ok
|
ELE13-01694
| Final | 10/7/2013 | 10/8/2013 | 10/8/2013 9:46:48 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Greg Traudt Final ok
|
ELE13-02783
| Electrical Rough-In | 10/7/2013 | 10/8/2013 | 10/8/2013 9:16:19 AM | A | PASS |
|
|
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Offices 1658 thru 1660 and 1609 wall rough in ok cover
|
ELE13-02469
| Electrical Rough-In | 10/7/2013 | 10/8/2013 | 10/8/2013 9:14:56 AM | A | PASS |
|
|
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Offices 1557, 58 and 1531 wall rough in ok cover
|