Inspections for the day of: Tuesday, October 8, 2013.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00708 ELE-Aging Inspection10/8/201310/8/201310/9/2013 3:58:15 PM DONE
Waiting on owner
ELE09-02411 ELE-Aging Inspection10/8/201310/8/201310/8/2013 4:58:12 PM DONE
Still under construction
ELE13-02793 Rough-In Permanent Service10/8/201310/8/201310/8/2013 4:44:19 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey
300.4 Bored holes less than 1 1/4" from stud surface shall be protected from physical damage. NM cable and low volt shall be protected.
210.52- Receptical outlets shall be installed so that no point measured along floor line is more than 6' from outlet. Master bed and family rm.
210.52- Receptical outlet shall be installed with in 6' of door opening measured along floor line. Down bed pocket door to bath.
* Out patio ceilings covered prior to inspection.
ELE13-02578 Electrical Rough-In10/8/201310/8/201310/8/2013 3:25:02 PMPPASS
wall cover. Danny on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen 12th floor unit 1200 wall rough in ok cover
ELE13-01908 Final10/8/201310/8/201310/8/2013 2:39:41 PMPPASS
House is open Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
ELE13-02548 Final10/7/201310/8/201310/8/2013 2:18:24 PMANH
Call Evan at ###-#### he will let you into the house.
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser Called contact and left 2 messages. Contractor to reschedule
ELE13-02023 Permanent Service10/7/201310/8/201310/8/2013 1:48:32 PMPPASS
Phone #: 2089546718 >> Inspection requested via mobile web by david luke p/s o/h n ok
ELE13-02023 Permanent Service10/7/201310/8/201310/8/2013 1:11:30 PMPPASS
Phone #: 2089546718 >> Inspection requested via mobile web by david luke p/s u/g n ok
ELE13-02189 Final10/8/201310/8/201310/8/2013 12:38:23 PMPFAIL
call first Phone #: ###-#### >> Inspection requested via web by PAT MILLER 210.52- Receptical outlet shall be installed at the end of peninsula.
422.30- A disconnecting means shall be provided to diconnect all ungrounded conductors. Built in oven
ELE13-02510 Electrical Rough-In10/8/201310/8/201310/8/2013 12:21:25 PMPPASS
Inspection for back entry Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Back entry ceiling and out lights rough in ok cover
ELE13-01617 Permanent Service10/7/201310/8/201310/8/2013 12:09:32 PMAPASS
don Phone #: ###-#### p/s o/h n ok
ELE13-02778 Rough-In Permanent Service10/7/201310/8/201310/8/2013 10:43:48 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman
rough in ok cover p/s o/h n ok
ELE13-02095 Final10/7/201310/8/201310/8/2013 10:23:38 AMAPASS
Please call Dianne (###-####) 30min ahead. Phone #: ###-#### >> Inspection requested via web by Brad Girard Final ok
ELE13-02509 Final10/7/201310/8/201310/8/2013 10:06:34 AMAPASS
Phone #: ###-#### >> Inspection requested via web by David Nelson final ok
ELE13-01694 Final10/7/201310/8/201310/8/2013 9:46:48 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Greg Traudt Final ok
ELE13-02783 Electrical Rough-In10/7/201310/8/201310/8/2013 9:16:19 AMAPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Offices 1658 thru 1660 and 1609 wall rough in ok cover
ELE13-02469 Electrical Rough-In10/7/201310/8/201310/8/2013 9:14:56 AMAPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Offices 1557, 58 and 1531 wall rough in ok cover