Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC12-00403 General Inspection10/8/201410/8/201410/8/2014 4:20:34 PM PART
Streets and gutters surrounding JUMP project are free of significant amounts of sediment from site. Dewatering filter units are installed at corner of 9th and Front and then discharging into MS4 on 9th. Water appears clear and also visual unimpaired at system discharge into Boise River by 9th Street brige.

Correction:
1. Need to provide a lined concrete washout facility on the west side of site per SWPPP. Concrete trucks washing out directly onto ground.

Called RP John Beck to make request.
ESC14-00432 General Inspection10/8/201410/8/201410/8/2014 3:20:01 PM FAIL
Permit and SWPPP information are posted at site entrance. Inspections being conducted by Syman Co..

Vegetative buffer and silt fence protecting creek/drain is installed properly and is effective. DI protection on Lizaso has adequate capcity. No water supression at site but no dust issues at time of inspection.

Corrections required:

1. Need to sweep up sidewalks and gutters on Lizaso along site.
2. Move piled dirt off broken chain link fence along Lizaso north of creek and have disturbed dirt below sidewalk grade.
3. Install effective vehicle tracking pad/construction entrance as indicated on site map per construction details. Only one entrance provided on Lizaso, though map indicates 2.
4. Cover or protect open sand/grease traps that have installed, especially one near sidewalk on Lizaso.
5. Repair section of silt fence where new storm drain outlet is being installed and take measures to prevent sediment from going downstream (ie check dam).

Called RP Eric Bird who put me in touch with on site supervisor Steven. I explained corrections and stated I would return Friday AM to check for completion.
ESC14-00315 General Inspection10/8/201410/8/201410/8/2014 1:27:53 PM PASS
ESC13-01153 Aging Inspection10/8/201410/8/201410/8/2014 12:27:19 PM PASS
Near completion. No sediment or materials leaving site. Some landscaping/interior work remains.
ESC14-00868 Random Inspection10/8/201410/8/201410/8/2014 12:13:46 PMPPART
Silt fence and sediment containment at east end of sewer pressure line project has not been disturbed and is preventing sediment runoff. Warm Springs is still closed to traffic, and work is mostly confined to the ACHD right-a-way.

They have not yet begun activity in the environmentally sensitve area by the west end of MA Williams park and Walling Creek/Greenbelt corridor.

Correction:

Need to sweep up the east access point as part of housekeeping BMP. Significant amount of loose sediment on roadway.
ESC13-00684 General Inspection10/8/201410/8/201410/8/2014 12:08:44 PM PASS
Landscaping and irrigation for open areas is currently being installed. Site sediment contaiment perimeteerr and vegetative buffer are in good condition with no evidence of discharge or sediment runoff. The Penn Canal is no longer flowing, so the landscaping will stabilize the north bank before next year's water season.

Checked the outlet of Walling Creek into Boise River downstream from site and other activity in Barber Valley and it is looking very clear with no color, odor or other visible water qualitiy issues.

No corrections at this time.
ESC14-00404 Site Preparation10/7/201410/8/201410/8/2014 11:23:51 AMAPASS
Don Phone #: ###-####

RP onsite with ESC plan and site map. BMPs installed per plan including inlet protection on the private onsite storm drains, straw wattle protection for the swale to the northeast of new building area.

Parking lot and staging area is mostly paved son no construction entrance/tracking pad. No MS4 in vicinity. Permit is posted on fence west of main building.

Approved for construction.
ESC14-00332 General Inspection10/8/201410/8/201410/8/2014 10:50:55 AM PASS
No ground disturbance yet. BMPs installed. Permit posted. No corrections required.
ESC14-00335 General Inspection10/8/201410/8/201410/8/2014 10:32:46 AM PASS
Construction complete and BLD finaled. Storage structure is up and pavement in place. Stockpile from work has been placed in adjacent material storage yard for futrure use. Stored in safe area (gravel lot) with no MS4 or surface water in vicinity.
ESC14-00335 DOC - Permit Finaled10/8/201410/8/201410/8/2014 10:30:45 AMPPASS
ESC13-01237 Aging Inspection10/8/201410/8/201410/8/2014 9:25:53 AM PASS