Inspections for the day of: Tuesday, October 9, 2001.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM01-02134 Final10/8/200110/9/200110/9/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 10/08/2001 at 14:25:46. Contact: ###-####.
PLM01-02919 Final10/8/200110/9/200110/9/2001 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 10/08/2001 at 22:18:40. Contact: ###-####. pex tubing shall not be installed within first 18 inches of water heater connection ( upc 604.11.2 ) 10/9/2001 11:38:16 AM
PLM01-03459 Groundwork10/9/200110/9/200110/9/2001 12:00:00 AMPFAIL
###-#### need to hang vent piping every 4 feet. need cleanout on break sink also need to protect piping passing through concret. need to change combo to san tee for floor drain ( upc 1002.4 vent opening below weir of trap ) need to change pvc pipe gluded in to abs fitting to abs pipe on 4x6 abs combo called plumbing contractor about correction,s 10/9/2001 3:34:53 PM
PLM01-02770 Final10/9/200110/9/200110/9/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 10/09/2001 at 08:41:08. Contact: ###-####.
PLM01-03469 Sprinkler (Final)10/9/200110/9/200110/9/2001 12:00:00 AMPPART
dennis-- ###-#### for backflow tie-in ok . ok to backfill contractor to recall when r.p. tested and certified 10/9/2001 1:51:08 PM
PLM01-03426 Plumbing Rough-in10/9/200110/9/200110/9/2001 12:00:00 AMPPASS
###-####