BLD18-02286
| BLD-Framing/Rough-in | 10/9/2018 | 10/9/2018 | 10/9/2018 5:11:59 PM | P | CANC |
|
|
Previous inspection entry should be Fail, not Cancel.
|
BLD18-02286
| BLD-Framing/Rough-in | 10/9/2018 | 10/9/2018 | 10/9/2018 5:10:15 PM | P | CANC |
|
|
Need straps at breaks in double top plates... Provide continuous bearing to footing for 3 ply beam, supporting 3 ply box truss, up stairs hallway... Need air/foam seal... See red paint
|
BLD18-02286
| BLD-Wall Bracing | 10/9/2018 | 10/9/2018 | 10/9/2018 5:06:17 PM | P | PEND |
|
|
Interior shear to be as per plans...
See red paint
|
BLD18-03048
| BLD-Framing/Rough-in | 10/9/2018 | 10/9/2018 | 10/9/2018 5:05:25 PM | P | PASS |
|
|
OK to cover
|
BLD17-03391
| BLD-Energy code compliance | 10/8/2018 | 10/9/2018 | 10/9/2018 5:05:09 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Clint Wall
|
BLD18-00983
| BLD-Final | 10/8/2018 | 10/9/2018 | 10/9/2018 5:04:57 PM | A | FAIL |
|
|
R-3 insulation needed at hot side of suppy, from water heater to house... Caulking needed at water heater vent penetration... Blower door test results to be posted... Egerss window, bedroom 3, to be no more than 44" from finished floor...
|
BLD18-00024
| BLD-Final | 10/8/2018 | 10/9/2018 | 10/9/2018 12:06:50 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Braxton Hansen
|
BLD18-00024
| DOC - Permit Finaled | 10/9/2018 | 10/9/2018 | 10/9/2018 12:06:41 PM | P | PASS |
|
|
|
BLD18-00024
| BLD-Blower Door Test Results | 10/9/2018 | 10/9/2018 | 10/9/2018 12:06:32 PM | A | DONE |
|
|
ACH50- 6
|
BLD18-03226
| BLD-Footing | 10/8/2018 | 10/9/2018 | 10/9/2018 12:06:07 PM | A | PASS |
|
|
call when on way // Tory Phone #: ###-####
|
BLD18-01982
| BLD-Footing | 10/8/2018 | 10/9/2018 | 10/9/2018 12:05:54 PM | A | PASS |
|
|
Work in progress
|