Inspections for the day of: Tuesday, October 9, 2018.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrandon Shaw
TitleBLD-COM/RES INSPECTOR
Phone #208-954-9358
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-02286 BLD-Framing/Rough-in10/9/201810/9/201810/9/2018 5:11:59 PMPCANC
Previous inspection entry should be Fail, not Cancel.
BLD18-02286 BLD-Framing/Rough-in10/9/201810/9/201810/9/2018 5:10:15 PMPCANC
Need straps at breaks in double top plates...
Provide continuous bearing to footing for 3 ply beam, supporting 3 ply box truss, up stairs hallway...
Need air/foam seal...
See red paint
BLD18-02286 BLD-Wall Bracing10/9/201810/9/201810/9/2018 5:06:17 PMPPEND
Interior shear to be as per plans...

See red paint
BLD18-03048 BLD-Framing/Rough-in10/9/201810/9/201810/9/2018 5:05:25 PMPPASS
OK to cover
BLD17-03391 BLD-Energy code compliance10/8/201810/9/201810/9/2018 5:05:09 PMAPASS
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD18-00983 BLD-Final10/8/201810/9/201810/9/2018 5:04:57 PMAFAIL
R-3 insulation needed at hot side of suppy, from water heater to house...
Caulking needed at water heater vent penetration...
Blower door test results to be posted...
Egerss window, bedroom 3, to be no more than 44" from finished floor...
BLD18-00024 BLD-Final10/8/201810/9/201810/9/2018 12:06:50 PMAPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD18-00024 DOC - Permit Finaled10/9/201810/9/201810/9/2018 12:06:41 PMPPASS
BLD18-00024 BLD-Blower Door Test Results10/9/201810/9/201810/9/2018 12:06:32 PMADONE
ACH50- 6
BLD18-03226 BLD-Footing10/8/201810/9/201810/9/2018 12:06:07 PMAPASS
call when on way // Tory Phone #: ###-####
BLD18-01982 BLD-Footing10/8/201810/9/201810/9/2018 12:05:54 PMAPASS
Work in progress