ELE17-02434
| ELE-Aging Inspection | 10/9/2019 | 10/9/2019 | 10/11/2019 3:05:39 PM | | FAIL |
|
|
No response from previous attemps. Doc expired
|
ELE19-02906
| Final | 10/9/2019 | 10/9/2019 | 10/9/2019 2:57:18 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams 300.15 All boxes shall be covered. East show window receptacle, and light 15' in not in. 440.6- Over current protection shall not exceed value on name plate. 45 max 50 amp installed.
|
ELE19-01226
| Electrical Rough-In | 10/8/2019 | 10/9/2019 | 10/9/2019 2:41:32 PM | P | PASS |
|
|
Units one and five Phone #: ###-#### Inspection requested via web by Garrett Collins Units noted rough in ok cover
|
ELE19-03602
| Electrical Rough-In | 10/9/2019 | 10/9/2019 | 10/9/2019 1:30:35 PM | P | PASS |
|
|
Shane Phone #: ###-#### Called Gemma and had ELE attached to BLD19-03611. Discussed if existing service can remain as is during remodel. Electrical engineer spec'ed out a service change for building. I am required to enforce electrical engineer drawings as approved by plan review. The print will required to be changed by electrical engineer documenting service is ok to remain as originally installed. As per Daryl DeGrange as noted above if engineer approves service ok to remain as is. Floor boxes and conduits rough in ok cover
|
ELE19-03751
| Rough-In Permanent Service | 10/7/2019 | 10/9/2019 | 10/9/2019 11:26:28 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk 314.17(B)- Where NM cable enters a hole in a metal box or cover it shall be protected from abrasion. Fireplace, no bushing on 14-2 entering box. 408.7- Unused breaker spaces shall be closed by approved means
|
ELE19-02801
| Final | 10/8/2019 | 10/9/2019 | 10/9/2019 10:48:58 AM | A | PASS |
|
|
Garage code 1957 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE18-03962
| Final | 10/8/2019 | 10/9/2019 | 10/9/2019 10:48:29 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson 210.8(A)- All bathroom receptacle outlets shall have GFCI protection.
|
ELE19-03496
| Temporary Service | 10/8/2019 | 10/9/2019 | 10/9/2019 9:57:59 AM | A | PASS |
|
|
Contact electrician on-site Shawn Evins. Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek t/s u/g n ok
|
ELE19-03729
| Rough-In Permanent Service | 10/8/2019 | 10/9/2019 | 10/9/2019 9:21:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|