Inspections for the day of: Tuesday, November 1, 2016.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-03442 BLD-Framing/Rough-in11/1/201611/1/201611/1/2016 4:46:07 PMPPART
Tyler Phone #: ###-####. This framing inspection was for a furout section in kithchen to accept a larger fridge. The scope of work on this permit only covers the kitchen remodel portion and does not cover any of the additional walls and added bedroom that were constructed with out permits. WIll post a seperate correction notice noting the that this permit does not dismiss the MIS permit case that has been created.
BLD16-04006 BLD-Footing11/1/201611/1/201611/1/2016 3:26:06 PMPNH
Brooke-please call for access Phone #: ###-####Called for access. upon arriving on site no one home, no call back. This patio has already been constructed, Will need to remove area around footing to verify frost depth and dimensions.
BLD16-01934 BLD-Ceiling Grid Inspection11/1/201611/1/201611/1/2016 3:05:27 PMPPASS
grid inspection ok. Noted that coorugated metal panels have been changed with barnwood siding, need smoke and flamespread values for interior finish. New restromm counters and lavs exceed the 34inch max height.
BLD16-03747 BLD-Framing/Rough-in11/1/201611/1/201611/1/2016 2:05:56 PMPPASS
Cyrus Phone #: ###-####
BLD16-03815 BLD-Conference11/1/201611/1/201611/1/2016 1:16:08 PMPPASS
Solar installation is installed to specs. Please call me if you would like me to meet you onsite with the approved plans. Phone #: ###-#### Inspection requested via web by Matthew Dunay
BLD16-03815 DOC - Permit Finaled11/1/201611/1/201611/1/2016 1:15:59 PMPPASS
BLD16-03123 BLD-Footing10/31/201611/1/201611/1/2016 12:19:32 PMAPASS
Ryan Phone #: ###-####
BLD16-03377 BLD-Footing10/31/201611/1/201611/1/2016 11:21:17 AMAPASS
###-####. footing at first 2ft. of ICF ok.
BLD16-03666 BLD-Foundation10/31/201611/1/201611/1/2016 10:38:18 AMAPART
Phone #: ###-####. North, east and west exterior stemwalls. Needs to add 90's at wall corners. Special inspector to verify.
BLD16-01367 BLD-Conference11/1/201611/1/201611/1/2016 10:20:11 AMAFAIL
Permit is past expiration PLEASE DO NOT EXPIRE, just need to make sure no work has been done right now. Thank you. Space is occupied. A correction notice was posted stating to pick up building permit at city hal and to obtain all required inspections to get a certificate of occupancy. 5 day notice.
BLD16-01104 BLD-Framing/Rough-in10/31/201611/1/201611/1/2016 10:05:28 AMAFAIL
Chad Phone #: ###-####. Complete fire block on 1st. floor behind tub. Nail off all simpson hangars. Ok to insulate, pending fire sprinkler rough in.
BLD16-01452 BLD-Footing10/31/201611/1/201611/1/2016 8:57:37 AMAPASS
Rick Phone #: ###-####. Footing infill at south side of building were existing transformer was located. Will have special inspection on epoxy for rebar.
BLD16-01934 BLD-Final10/31/201611/1/201611/1/2016 8:33:49 AMACANC
Jeff Phone #: ###-####. Moved to pm inspection. Will be ceiling grid inspection. Needs fire/life/safety finals.