Inspections for the day of: Friday, November 1, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02495 Final11/1/201911/1/201911/1/2019 2:56:36 PMPPASS
I should be on-site by 2 pm. Access is available throughout the day Phone #: ###-#### Inspection requested via web by Sean Patton
Final ok-no Occ card to sign
ELE19-03092 Electrical Rough-In11/1/201911/1/201911/1/2019 2:56:07 PMPPASS
Grid ceiling Phone #: ###-#### Inspection requested via web by Jim Williams
Suspended ceiling in lobby and dining area only ok to cover
ELE19-02435 Final11/1/201911/1/201911/1/2019 2:06:59 PMPFAIL
For access please call Terry 1/2 hr prior to inspection ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott
210.8 All reseptacles located within 6' of a sink shall be GFCI protected
110.25 lockable disc for all hard wired appliances(cooktop,oven,dishwasher,micro)
ELE19-02468 Final10/31/201911/1/201911/1/2019 1:37:52 PMPPASS
Call Jeremy 1st please Phone #: ###-#### Inspection requested via web by Ryan Wake
Final ok-Occ card signed
ELE19-04187 Electrical Rough-In10/30/201911/1/201911/1/2019 11:53:01 AMAPASS
Electrical rough-in for HVAC upgrades.
Must call number above before arrival for access to the site.
Tight security for Airport Custom and Boarder Patrol Building. Phone #: ###-####
Inspection requested via web by Kevin Perez
Electrical installed for Duct heaters and new service in equipment room ok to proceed...
ELE19-04186 Temporary Service10/31/201911/1/201911/1/2019 11:31:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Bonnie Page
Wrong Address given on temp pole as per permit # and request
t/s u/g n ok
ELE19-04199 Electrical Rough-In10/31/201911/1/201911/1/2019 11:27:47 AMAPASS
please call so i can get you in
###-####
eddy Phone #: ###-#### Inspection requested via web by Eddy Udry
Bath and laundry by garage and minimal work fished in kitchen ok to cover
ELE19-03947 Final10/31/201911/1/201911/1/2019 10:51:35 AMAPASS
Homeowner has to take child to school at 9 AM, but will be home to let inspector in at all other times. Phone #: ###-#### Inspection requested via web by Sarah Schuller
Solar Array final ok
ELE19-00982 Final10/31/201911/1/201911/1/2019 10:19:41 AMAFAIL
Ben Phone #: ###-####
210.52 REceptacle required within 24" of a range in both directions
210.8 GFCI protection required for all bathroom receptacles(Master bath)
210.12 AFCI protection for bedrooms(excersize room has rods in closets)
110.25 Lockable means of Disc for all hard wired appliances(oven)
open ground in back rooms
Hall bath receptacle in-op next to GFCI
BCO-no violation shall be retained
Replace flex and receptacle in front of house
ELE19-03229 Electrical Rough-In10/31/201911/1/201911/1/2019 9:52:23 AMAPASS
CONTACT: MIKE MULVAHILL Ceiling inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden
Ceiling ok to cover
ELE19-03907 Rough-In Permanent Service10/31/201911/1/201910/31/2019 8:37:53 AMACANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk