Inspections for the day of: Friday, November 1, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04923 DOC - Permit Finaled11/1/201911/1/201911/1/2019 4:13:57 PMPPASS
final ok
MEC19-04923 Pressure Test10/31/201911/1/201911/1/2019 4:13:34 PMPPASS
please call homeowner 20 min before heading out
she will be back home after work around 2:30 pm
thanks. Phone #: ###-#### Inspection requested via web by Manuel Canto
- 20lb gas pressure test ok
MEC19-03075 Final10/30/201911/1/201911/1/2019 3:38:07 PMPFAIL
Please call when youre headed over if possible. Phone #: ###-#### Inspection requested via web by Misty Merry
- A/C needs locking caps installed on service ports
- line set in crawl needs supported
- flue in crawl needs supported and a draft stop installed where flue enters chimney
MEC19-04908 Rough-in11/1/201911/1/201911/1/2019 3:00:04 PMPPART
Requesting Cover Inspection. Please contact Mark prior to coming out. ###-####. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- partial R/I for pre rock ok on end unit only
- exhaust fan termination 1st floor will terminate side of building on end units and a soffit will be built for center units to terminate between door and window
- talked with contractor and builder about condensates for cooling coils and where they will drain. RFI being built for condensates
MEC19-04938 Final11/1/201911/1/201911/1/2019 2:34:04 PMPPASS
Please call home owner when you are on your way so he can meet you there. Thank you.travis ###-#### Phone #: ###-#### Inspection requested via web by jeremy wanders
- furnace only co ok
MEC19-03768 Final11/1/201911/1/201911/1/2019 1:57:14 PMPPASS
Access: 9378
Jarrod: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
- final ok
MEC19-04296 Rough-in10/31/201911/1/201911/1/2019 1:57:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
- R/I ok
MEC19-04892 Rough-in10/31/201911/1/201911/1/2019 11:30:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
- firplace R/I ok
MEC19-04076 Final11/1/201911/1/201911/1/2019 11:28:22 AMAPASS
- final ok
MEC19-04715 Rough-in10/31/201911/1/201911/1/2019 10:49:25 AMAPASS
Cover inspection please. Cy ###-#### Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- R/I ceiling cover ok
- still need to see gas piping and pressure test on roof done by others
MEC19-01561 Rough-in11/1/201911/1/201911/1/2019 10:47:08 AMAPASS
R/I ceiling cover ok
- still need to gas piping pressure test by others on the roof
MEC19-04076 Rough-in10/31/201911/1/201911/1/2019 9:56:33 AMAPASS
Please call Ernie for access
Phone #: ###-#### Inspection requested via web by Nicholas Paige
- R/I ceiling cover ok
MEC19-04878 Final10/30/201911/1/201911/1/2019 9:55:15 AMAFAIL
Inspection requested via web by Michael Stimpson
- ductless split ok
- need to see an electrical permit issued
MEC19-04907 Final10/31/201911/1/201911/1/2019 9:13:03 AMAPASS
Please call homeowner, Chuck, with eta to ensure he is home. Thanks! Phone #: ###-#### Inspection requested via web by Alyssa Cromwell
- furnace only co ok
MEC19-04907 Pressure Test10/31/201911/1/201911/1/2019 9:12:39 AMACANC
Please call homeowner, Chuck, with eta to ensure he is home. Thanks! This will be for a flue pressure test. Phone #: ###-#### Inspection requested via web by Alyssa Cromwell
MEC19-01508 Mec-Aging Inspection11/1/201911/1/201911/1/2019 8:50:04 AM PASS
WIP