Inspections for the day of: Thursday, November 10, 2005.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03998 Final11/3/200511/10/200511/10/2005 4:33:34 PMPFAIL
POWER TO A PRESS. ADD LIGHTING ABOVE NEW PRESS. HOOK UP POWER TO LIGHT TABLE.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell cor.and red tag posted called 110.2#3 printing press not listed,or tested, press shall not be used till tested ,listed and tag install by testing lab
ELE05-04006 Final11/9/200511/10/200511/10/2005 3:51:54 PMPNH
Phone #: ###-#### Internet Inspection Request from: Vince Bourner called left message,, need contractor or other inspector to be there for inspection
ELE05-04057 Final11/10/200511/10/200511/10/2005 3:06:27 PMPNH
connie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles only person there was a child told owner I had to have an adult there
ELE05-01889 Final11/10/200511/10/200511/10/2005 2:22:39 PMPPASS
###-#### or ###-#### ok card signed
ELE05-03484 Final11/10/200511/10/200511/10/2005 1:45:54 PMPFAIL
gayle; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa not ready no power to shop reinspection fee
ELE04-02852 Electrical Rough-In11/7/200511/10/200511/10/2005 1:42:11 PMPFAIL
nick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles only 2 walls in living rm ok dinning rm has violations 210.52(B) only what code allows on small appliance branch circuit can be on circuit
ELE05-04090 Permanent Service11/10/200511/10/200511/10/2005 12:45:22 PMPPASS
rocky - ###-#### p/s o/h rec. ok
ELE05-03016 Electrical Rough-In11/10/200511/10/200511/10/2005 12:33:49 PMPFAIL
please inspect underground to post light. Thank you!; Phone #: ###-#### Internet Inspection Request from: William Zerfas cor called corrections not made, 300.5 (D)
ELE05-04051 Temporary Service11/9/200511/10/200511/10/2005 11:55:00 AMAPASS
hz; Phone #: ###-#### Internet Inspection Request from: Barbara Moore t/s u/g new ok
ELE05-04047 Rough-In Permanent Service11/9/200511/10/200511/10/2005 11:45:32 AMAFAIL
Scheduled by a contractor via Hello! on 11/9/2005 at 5:22:56 PM. Contact: ###-####. cor. called left message all violations not corrected 300.4 nail plates and 11/4" reinspection fee due
ELE05-03820 Electrical Rough-In11/9/200511/10/200511/10/2005 10:22:40 AMAFAIL
Ceiling inspection for WFS Financial Tenant Improvement for RA Schultz General Contractor; Phone #: ###-#### x39 Internet Inspection Request from: Kristopher wilson cor. do not cover posted called left message, 300.11 support wires for cables shall be secured from structural ceiling to grid , not fixtures
ELE05-03790 Electrical Rough-In11/9/200511/10/200511/10/2005 9:41:55 AMAPASS
THIS IS FOR A CEILING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL STEVE NUXOLL; Phone #: ###-#### Internet Inspection Request from: Jeff cielings okRadford
ELE05-01848 Rough-In Permanent Service11/9/200511/10/200511/10/2005 9:08:04 AMAPART
Corrections. Contact Harvey Reyna.; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA r/i ok only cor posted 230.24(A( exception #3 needs 18" from drip loop to roof, 314.20 outside boxes shall be flush with siding called
ELE05-01889 Final11/8/200511/10/200511/10/2005 8:29:57 AMACANC
dustin; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called will do it in PM
ELE05-03514 Final11/9/200511/10/200511/10/2005 7:24:48 AMAPASS
Thanks Jack!; Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt ok
ELE05-04090 Electrical Rough-In11/10/200511/10/200511/10/2005 12:00:00 AMPCANC
###-#### - rocky Note: after 2:30 or so if possible