ELE05-03998
| Final | 11/3/2005 | 11/10/2005 | 11/10/2005 4:33:34 PM | P | FAIL |
|
|
POWER TO A PRESS. ADD LIGHTING ABOVE NEW PRESS. HOOK UP POWER TO LIGHT TABLE.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell cor.and red tag posted called 110.2#3 printing press not listed,or tested, press shall not be used till tested ,listed and tag install by testing lab
|
ELE05-04006
| Final | 11/9/2005 | 11/10/2005 | 11/10/2005 3:51:54 PM | P | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Vince Bourner called left message,, need contractor or other inspector to be there for inspection
|
ELE05-04057
| Final | 11/10/2005 | 11/10/2005 | 11/10/2005 3:06:27 PM | P | NH |
|
|
connie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles only person there was a child told owner I had to have an adult there
|
ELE05-01889
| Final | 11/10/2005 | 11/10/2005 | 11/10/2005 2:22:39 PM | P | PASS |
|
|
###-#### or ###-#### ok card signed
|
ELE05-03484
| Final | 11/10/2005 | 11/10/2005 | 11/10/2005 1:45:54 PM | P | FAIL |
|
|
gayle; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa not ready no power to shop reinspection fee
|
ELE04-02852
| Electrical Rough-In | 11/7/2005 | 11/10/2005 | 11/10/2005 1:42:11 PM | P | FAIL |
|
|
nick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles only 2 walls in living rm ok dinning rm has violations 210.52(B) only what code allows on small appliance branch circuit can be on circuit
|
ELE05-04090
| Permanent Service | 11/10/2005 | 11/10/2005 | 11/10/2005 12:45:22 PM | P | PASS |
|
|
rocky - ###-#### p/s o/h rec. ok
|
ELE05-03016
| Electrical Rough-In | 11/10/2005 | 11/10/2005 | 11/10/2005 12:33:49 PM | P | FAIL |
|
|
please inspect underground to post light. Thank you!; Phone #: ###-#### Internet Inspection Request from: William Zerfas cor called corrections not made, 300.5 (D)
|
ELE05-04051
| Temporary Service | 11/9/2005 | 11/10/2005 | 11/10/2005 11:55:00 AM | A | PASS |
|
|
hz; Phone #: ###-#### Internet Inspection Request from: Barbara Moore t/s u/g new ok
|
ELE05-04047
| Rough-In Permanent Service | 11/9/2005 | 11/10/2005 | 11/10/2005 11:45:32 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/9/2005 at 5:22:56 PM. Contact: ###-####. cor. called left message all violations not corrected 300.4 nail plates and 11/4" reinspection fee due
|
ELE05-03820
| Electrical Rough-In | 11/9/2005 | 11/10/2005 | 11/10/2005 10:22:40 AM | A | FAIL |
|
|
Ceiling inspection for WFS Financial Tenant Improvement for RA Schultz General Contractor; Phone #: ###-#### x39 Internet Inspection Request from: Kristopher wilson cor. do not cover posted called left message, 300.11 support wires for cables shall be secured from structural ceiling to grid , not fixtures
|
ELE05-03790
| Electrical Rough-In | 11/9/2005 | 11/10/2005 | 11/10/2005 9:41:55 AM | A | PASS |
|
|
THIS IS FOR A CEILING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL STEVE NUXOLL; Phone #: ###-#### Internet Inspection Request from: Jeff cielings okRadford
|
ELE05-01848
| Rough-In Permanent Service | 11/9/2005 | 11/10/2005 | 11/10/2005 9:08:04 AM | A | PART |
|
|
Corrections. Contact Harvey Reyna.; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA r/i ok only cor posted 230.24(A( exception #3 needs 18" from drip loop to roof, 314.20 outside boxes shall be flush with siding called
|
ELE05-01889
| Final | 11/8/2005 | 11/10/2005 | 11/10/2005 8:29:57 AM | A | CANC |
|
|
dustin; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called will do it in PM
|
ELE05-03514
| Final | 11/9/2005 | 11/10/2005 | 11/10/2005 7:24:48 AM | A | PASS |
|
|
Thanks Jack!; Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt ok
|
ELE05-04090
| Electrical Rough-In | 11/10/2005 | 11/10/2005 | 11/10/2005 12:00:00 AM | P | CANC |
|
|
###-#### - rocky Note: after 2:30 or so if possible
|