Inspections for the day of: Tuesday, November 12, 2002.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM02-03206 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 11/12/2002 at 06:23:00. Contact: ###-####.need to test grease intercepter and plumber missed floor sink in groundwork need to install trap and vent and retest ground work ok to cover portion of ground work that was tested contractor to recall when ready 11/12/2002 12:02:32 PM
PLM02-03430 Groundwork11/12/200211/12/200211/12/2002 12:00:00 AMAPASS
PLM02-02996 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMAPASS
PLM02-03439 Sprinkler (Final)11/8/200211/12/200211/12/2002 12:00:00 AMANR
not ready 11/12/2002 1:01:34 PM
PLM02-03429 Water and/or Sewer11/8/200211/12/200211/12/2002 12:00:00 AMAPASS
PLM02-03007 Plumbing Rough-in11/11/200211/12/200211/12/2002 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 11/11/2002 at 08:13:54. Contact: ###-####. provide premise protection need to pipe t&p to outside building test on D.W.V. test ok will need to retest water after premise protection is installed contractor to recall when ready 11/12/2002 2:19:00 PM
PLM02-03448 Final11/12/200211/12/200211/12/2002 12:00:00 AMPNR
fn -nancy ###-####
PLM02-03451 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMPPART
###-#### andy need to move pex from can lighting and retest water system contractor to recall when ready 11/12/2002 5:48:52 PM
PLM02-03448 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMPPASS
PLM02-03206 Groundwork11/12/200211/12/200211/12/2002 12:00:00 AMPPASS
PLM02-03254 Water and/or Sewer11/12/200211/12/200211/12/2002 12:00:00 AMPPASS
john; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
PLM02-03440 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMPPASS
jason ###-####
PLM02-03367 Water and/or Sewer11/12/200211/12/200211/12/2002 12:00:00 AMPFAIL
clifford; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie upc 608.5 need approved material for t&p pipe to outside with in six inches of ground and turned downward left correction notice 11/12/2002 4:13:09 PM
PLM02-03011 Plumbing Rough-in11/12/200211/12/200211/12/2002 12:00:00 AMPPASS
###-#### craig