Inspections for the day of: Wednesday, November 12, 2008.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02907 Final11/12/200811/12/200811/12/2008 4:01:24 PMPFAIL
shawn Phone #: ###-#### met owner had conference needs conn for GEC , bond hot and cold with #4 copper, isolate grds and neutrals at subpanel, install raceway for conductors between p/s and subpanel or use SER, also needs mast straped and supported, and 4wire recepts and pigtails for range and dryer told owner to request a p/s inspection
ELE08-02949 Electrical Rough-In11/12/200811/12/200811/12/2008 3:46:27 PMPCANC
If I get a call from you I can meet you there for inspection. Thanks, Eric Phone #: ###-#### Internet Inspection Request from: Eric Schroeder contr called and canceled request, I told when ready , make sure ele is attached to bld
ELE08-02432 Rough-In Permanent Service11/11/200811/12/200811/12/2008 3:34:32 PMPFAIL
Mark is at the job site and can be reached at ###-#### Phone #: ###-#### Internet Inspection Request from: Mike TenHulzen
all violations not corrected, also needs listed choke main water bond in rigid inside of building, and shall bond CT can with both paralled conductors or a 1/0 copper
ELE08-03012 Electrical Rough-In11/12/200811/12/200811/12/2008 2:54:41 PMPCANC
don Phone #: ###-####2 - please call 1/2 hr prior contr called and canceled
ELE08-02588 Final11/11/200811/12/200811/12/2008 2:53:44 PMAPASS
Garage code, 6175, thanks, TW. Phone #: ###-#### Internet Inspection Request from: Stephen Kren ok
ELE08-03015 Electrical Rough-In11/12/200811/12/200811/12/2008 2:16:45 PMPPART
Please call 30 mins prior to inspection so he can meet ya there--Mike Phone #: ###-####center core area u/g ok
ELE08-02671 Final11/12/200811/12/200811/12/2008 1:15:12 PMPPASS
jared Phone #: ###-#### ok
ELE08-02746 Electrical Rough-In11/12/200811/12/200811/12/2008 12:52:00 PMPPASS
greg Phone #: ###-#### ok
ELE08-02908 Final11/12/200811/12/200811/12/2008 12:18:58 PMPNR
Jeremy Phone #: ###-#### met contr not rready
ELE08-03005 Electrical Rough-In11/11/200811/12/200811/12/2008 11:08:56 AMAPASS
Please give me a call so i can meet you there. Thank you. Phone #: ###-#### Internet Inspection Request from: jason shifflett r/i ok
ELE08-01449 Final11/12/200811/12/200811/12/2008 11:08:12 AMPPART
Final Inspection - partial (question call Troy ###-#### ) Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe
conf ok
ELE08-02746 Electrical Rough-In11/10/200811/12/200811/12/2008 10:37:10 AMAFAIL
Greg Phone #: ###-#### corr before final shall provide outlet for fixed panel back door , also remove outlet above baseboard heater, for r/i needs to secure boxes in attis and staple cables 12" of recess fixtures, and 8" of plastic boxes
ELE08-02999 Temporary Service11/10/200811/12/200811/12/2008 10:11:04 AMAPASS
dustin Phone #: ###-#### t/s o/h new ok
ELE08-02417 Final11/11/200811/12/200811/12/2008 9:46:19 AMAPASS
call for code # Phone #: ###-#### Internet Inspection Request from: Rick Beckman ok
ELE08-02801 Electrical Rough-In11/10/200811/12/200811/12/2008 9:25:27 AMAPART
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot walls and ceilings ok called needs required sign circuit 600.5
ELE08-02851 Final11/10/200811/12/200811/12/2008 8:30:14 AMAPASS
Call for access Phone #: ###-#### Internet Inspection Request from: Rick ok no card
ELE08-02851 Electrical Rough-In11/10/200811/12/200811/12/2008 8:29:44 AMAPASS
Ceiling grid inspection Call for access Phone #: ###-#### Internet Inspection Request from: Rick Beckman called secure MC at recess lights
ELE08-02120 Electrical Rough-In11/11/200811/12/200811/12/2008 8:04:58 AMAPART
Ceiling inspection. Chris is the onsite contact, his no. is ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Shawna Gates 2nd floor ceilings anop