Inspections for the day of: Tuesday, November 12, 2013.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03070 Final11/8/201311/12/201311/13/2013 12:09:46 PMAPASS
Phone #: ###-#### >> Inspection requested via web by steve ragan correction done final ok
ELE13-02889 Rough-In Permanent Service11/12/201311/12/201311/12/2013 5:52:54 PMPPASS
eric Phone #: ###-#### rough-in concrete encased electrode, p/s o/h rec ok
ELE13-03136 Electrical Rough-In11/11/201311/12/201311/12/2013 5:22:41 PMPPASS
The later the better, doing a service change and could use a little later inspection.
Thanks,
Dustin Phone #: ###-#### >> Inspection requested via web by Dustin Kuester rough-in ok cover addition
ELE13-03136 Permanent Service11/12/201311/12/201311/12/2013 5:21:34 PMPPASS
The later the better, doing a service change and could use a little later inspection.
Thanks,
Dustin Phone #: ###-#### >> Inspection requested via web by Dustin Kuester p/s o/h rec ok
ELE13-03163 Final11/12/201311/12/201311/12/2013 4:54:57 PMPPART
Mark Phone #: ###-####-please final this permit also when you final ELE13-00837 Fuel dispensers not complete
ELE13-00837 Final11/12/201311/12/201311/12/2013 4:49:39 PMPPASS
Mark Phone #: ###-#### Hanger and office building final ok
ELE13-02430 Electrical Rough-In11/12/201311/12/201311/12/2013 4:16:36 PMPPASS
Inspect for exterior warehouse walls. Contact on job is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover
ELE13-02868 Final11/11/201311/12/201311/12/2013 3:46:38 PMAPASS
Final insp kitchen electrical. Phone #: ###-#### >> Inspection requested via web by Rex Boyles final ok
ELE13-02872 Final11/11/201311/12/201311/12/2013 2:19:19 PMPPASS
Building is open today Phone #: ###-#### >> Inspection requested via web by Celinda Winters final ok
ELE13-03143 Rough-In Permanent Service11/11/201311/12/201311/12/2013 1:55:53 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey NEC 210.52(2) receptacle spacing NEC 406.5(E) Receptacles shall not be installed in face up position. plant shelf
ELE13-02223 Final11/12/201311/12/201311/12/2013 12:57:22 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Not all receptacles have power, no breakers off. Furnace flex requires abrastion protection.
ELE13-03144 Permanent Service11/10/201311/12/201311/12/2013 12:35:54 PMANR
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Should of been scheduled as temp.service
ELE13-03144 Temporary Service11/12/201311/12/201311/12/2013 12:34:59 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
ELE12-02735 Rough-In Permanent Service11/8/201311/12/201311/12/2013 12:10:20 PMACANC
A ceiling inspection for the CCD number 011 is being requested. Please contact Bud Horsely with any questions. Phone #: ###-#### >> Inspection requested via web by Clint Tate
ELE12-02735 Electrical Rough-In11/12/201311/12/201311/12/2013 12:09:23 PMPPASS
A ceiling inspection for the CCD number 011 is being requested. Please contact Bud Horsely with any questions. Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover ceiling grid
ELE12-02735 Electrical Rough-In11/8/201311/12/201311/12/2013 12:05:14 PMAPASS
A wall inspection for the 2B phase of this project is being requested. Please contact Bud Horsely with any questions. Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover
ELE13-02649 Final11/10/201311/12/201311/12/2013 10:11:10 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok
GCE13-00180 GCE-Rough-In Permanent Service11/8/201311/12/201311/12/2013 9:39:01 AMAPASS
Alan ###-#### call first p/s u/g n ok
GCE13-00119 GCE-Final11/8/201311/12/201311/12/2013 9:19:19 AMAFAIL
Brandon ###-#### NEC 210.8(A)(3) All outdoor 15 and 20 ampere 1120 volt receptacle shall be GFCI protected , Furnace switch requires on/off labeling
ELE13-03152 Temporary Service11/12/201311/12/201311/12/2013 8:52:20 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman t/s u/g n ok
ELE13-03151 Temporary Service11/12/201311/12/201311/12/2013 8:51:03 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman t/s u/g n ok
ELE11-02123 ELE-Aging Inspection11/12/201311/12/201311/12/2013 8:40:06 AM DONE
still under construction, waiting for ordered fixtures
ELE13-03149 Electrical Rough-In11/11/201311/12/201311/12/2013 8:24:21 AMAPASS
I will be at the remodel by 8:00 to let you in the home and walk you through the scope of work. Phone #: ###-#### >> Inspection requested via web by David Nelson rough-in ok cover no smoke detectors have been roughed