Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01812 Electrical Rough-In11/11/201511/12/201511/12/2015 3:47:01 PMPPASS
Inspection for the site pole base. Phone #: ###-#### Inspection requested via web by William Salts 2 west pole bases rough in ok cover
ELE15-02489 Electrical Rough-In11/12/201511/12/201511/12/2015 3:13:41 PMPPASS
Please inspect the ceiling for cover. Phone #: ###-#### Inspection requested via web by Spencer McLean Area 2.3 grid rough in ok cover
ELE15-03677 Final11/12/201511/12/201511/12/2015 3:08:41 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Fletcher Permanent service inspection required.
Spoke with contractor on this permit he did not install service pedistal on lot. Asked him to find out who did and call me so I can verify responcible party.

550.10(I)- A metal or rigid non-metallic conduit from disconnecting means to underside of mobile home shall be installed
250.24- Grounding electrode system required. Unable to verify existing.
ELE15-03515 Final11/11/201511/12/201511/12/2015 2:05:51 PMPPASS
We are requesting a final inspection for tomorrow 11/12/15 in the afternoon. Our contact is Trent Hammon @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Final ok
ELE15-03457 Final11/11/201511/12/201511/12/2015 1:42:53 PMPFAIL
Phone #: ###-#### Inspection requested via web by Emmet Bushman
110.12- As you enter 3 receptacle outlets on wall to right not working.
314.25- All boxes shall have covers.
ELE15-03056 Final11/12/201511/12/201511/12/2015 1:05:35 PMAFAIL
All work is complete. Low voltage boxes, for speakers, are incomplete, owner to finish. Side door is open for access into shop. Phone #: ###-#### Inspection requested via web by Kurt Carlson
406.12(A)- All areas specified in 210.52, all 120volt 15 and 20 amp receptacle outlets shall be listed tamper resistant receptacles.
ELE15-03672 Final11/11/201511/12/201511/12/2015 12:43:26 PMAPASS
new pylon sign Phone #: ###-#### Inspection requested via web by Mark Morgan Circuit to sign underground final ok
ELE15-03672 Electrical Rough-In11/12/201511/12/201511/12/2015 12:42:49 PMPPASS
new pylon sign Phone #: ###-#### Inspection requested via web by Mark Morgan Underground to sign rough in ok cover
ELE15-03657 Rough-In Permanent Service11/10/201511/12/201511/12/2015 12:14:40 PMAPASS
Phone #: ###-#### Inspection requested via web by Neal Rumsey Rough in ok cover p/s o/h n ok
ELE15-03669 Electrical Rough-In11/11/201511/12/201511/12/2015 11:43:49 AMAPASS
If you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan South back addition of master bed, bath, closet, laundry areas rough in ok cover
ELE15-02696 Final11/11/201511/12/201511/12/2015 11:21:58 AMAFAIL
Bob Thomas Phone #: ###-#### Inspection requested via web by Kerri Hamilton
110.7- Wiring integrity- 2 receptacle outlets not working. Post outlet and north hall. Several luminaires not working, some flash.
210.8(B)- Receptacle outlets located within 6' of sink shall have GFCI protection.
ELE15-03671 Electrical Rough-In11/11/201511/12/201511/12/2015 10:46:33 AMAPASS
Gate next to garage is open , yellow city permit on gate Phone #: ###-#### Inspection requested via web by Jesse Fuentes Sunroom in rear central of back. Rough in ok cover
ELE15-02787 Final11/10/201511/12/201511/12/2015 10:32:18 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
No access to garage. Key did not work on garage.
ELE15-02831 Final11/10/201511/12/201511/12/2015 10:27:58 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
210.52(C)(3)- If peninsula counter space is 24" or more from its connecting edge a receptacle outlet shall be located at end.
ELE15-03654 Rough-In Permanent Service11/10/201511/12/201511/12/2015 9:49:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Told if foam seal again before inspection job will fail until all is removed. Rough in ok cover p/s u/g n ok
ELE15-03221 Final11/12/201511/12/201511/12/2015 9:32:31 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn
No access to garage walls due to trash build up. Remove and recall.
ELE15-03086 Final11/12/201511/12/201511/12/2015 8:57:25 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE15-03203 Final11/12/201511/12/201511/12/2015 8:44:00 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE15-03590 Rough-In Permanent Service11/10/201511/12/201511/12/2015 8:01:36 AMACANC
Phone #: ###-#### Inspection requested via web by daniel bibikov Duplicate request.
ELE15-03590 Final11/10/201511/12/201511/12/2015 7:52:03 AMACANC
Phone #: ###-#### Inspection requested via web by daniel bibikov Needed rough in permanent service
ELE13-00910 ELE-Aging Inspection11/12/201511/12/201511/12/2015 7:51:01 AM CANC
ELE13-00903 ELE-Aging Inspection11/12/201511/12/201511/12/2015 7:49:52 AM CANC
ELE13-00855 ELE-Aging Inspection11/12/201511/12/201511/12/2015 7:49:22 AM CANC
ELE13-00908 ELE-Aging Inspection11/12/201511/12/201511/12/2015 7:49:08 AM CANC
ELE15-03515 Final11/6/201511/12/201511/11/2015 3:53:23 PMACANC
We are requesting a final inspection for Thursday 11/12/15 in the AM. Our contact for this is Trent @ ###-####. Thank you Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
ELE15-03396 Electrical Rough-In11/10/201511/12/201511/10/2015 10:11:25 AMACANC
We need an underground inspection for Thursday. Thank you! Phone #: ###-#### >> Inspection requested via web by Stacie Tasker Inspection cancelled from web by: Stacie Tasker