ELE15-01056
| Rough-In Permanent Service | 11/11/2015 | 11/12/2015 | 11/12/2015 4:35:21 PM | P | PASS |
|
|
Conduit is replaced Phone #: ###-#### Inspection requested via web by John Harvey p/s u/g n ok
|
ELE15-03550
| Final | 11/12/2015 | 11/12/2015 | 11/12/2015 4:12:24 PM | P | PASS |
|
|
Please call for access info - Jonathan Phone #: ###-#### final ok
|
ELE15-03675
| Electrical Rough-In | 11/11/2015 | 11/12/2015 | 11/12/2015 3:16:10 PM | P | PASS |
|
|
floor heat inspection Phone #: ###-#### Inspection requested via web by Ryan Wake rough-in ok cover listed CSA floor heat
|
ELE15-02938
| Conference | 11/12/2015 | 11/12/2015 | 11/12/2015 2:37:08 PM | P | DONE |
|
|
Bob
Please call me when you get a chance about this Mike B ; B ###-#### Phone #: ###-#### Inspection requested via web by Mike Cole Contractor confirming required IMC raceways in roof decking
|
ELE15-03681
| Electrical Rough-In | 11/12/2015 | 11/12/2015 | 11/12/2015 2:18:53 PM | P | PASS |
|
|
underground only. Thanks Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
|
ELE15-03680
| Electrical Rough-In | 11/12/2015 | 11/12/2015 | 11/12/2015 2:18:04 PM | P | PASS |
|
|
underground only. thanks! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
|
ELE15-03678
| Electrical Rough-In | 11/12/2015 | 11/12/2015 | 11/12/2015 2:17:20 PM | P | PASS |
|
|
underground only. Thanks! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
|
ELE15-03676
| Electrical Rough-In | 11/12/2015 | 11/12/2015 | 11/12/2015 2:13:13 PM | P | PASS |
|
|
underground only thanks!!! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
|
ELE15-03204
| Final | 11/12/2015 | 11/12/2015 | 11/12/2015 1:48:47 PM | P | FAIL |
|
|
Early afternoon if possible, please call Brad (###-####) 30 minutes ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard NEC 210.8 GFCI protection for kitchen counter receptacles
|
ELE15-03668
| Temporary Service | 11/11/2015 | 11/12/2015 | 11/12/2015 1:32:13 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rhonda Yoast t/s o/h n ok
|
ELE15-03666
| Final | 11/11/2015 | 11/12/2015 | 11/12/2015 1:23:50 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Felin Receptacle added on furnace for condensate pump in the garage requires GFCI protection NEC 210.8(A)(2)
|
ELE15-02808
| Final | 11/11/2015 | 11/12/2015 | 11/12/2015 12:48:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Zane Robertson final ok
|
ELE15-03635
| Conference | 11/9/2015 | 11/12/2015 | 11/12/2015 12:20:51 PM | A | DONE |
|
|
Joseph Phone #: ###-#### Discussed with homeowner electrical requirements for remodel and new addition
|
ELE15-03576
| Permanent Service | 11/11/2015 | 11/12/2015 | 11/12/2015 11:45:54 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Atkins correction done,p/s u/g rec ok
|
ELE15-03595
| Permanent Service | 11/10/2015 | 11/12/2015 | 11/12/2015 11:28:52 AM | A | PASS |
|
|
If you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction done, p/s o/h rec ok
|
ELE15-03422
| Electrical Rough-In | 11/10/2015 | 11/12/2015 | 11/12/2015 11:01:40 AM | A | PASS |
|
|
Underground Inspection. Contact Travis Hust Phone #: ###-#### Inspection requested via web by Cathy Duchek correction done verified conduit depth, south parking lot, westside edge
|
ELE15-02881
| Final | 11/12/2015 | 11/12/2015 | 11/12/2015 10:16:25 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
|
ELE15-02901
| Final | 11/11/2015 | 11/12/2015 | 11/12/2015 10:04:54 AM | A | PASS |
|
|
josh Phone #: ###-#### Inspection requested via web by kim grundhauser final ok
|
ELE15-02577
| Final | 11/10/2015 | 11/12/2015 | 11/12/2015 9:49:36 AM | A | FAIL |
|
|
Lockbox 1967, if you have any questions, please call Calvin at ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan No power to Master bath vanity receptacles
|
ELE15-03663
| Temporary Service | 11/11/2015 | 11/12/2015 | 11/12/2015 9:20:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE15-03664
| Temporary Service | 11/11/2015 | 11/12/2015 | 11/12/2015 9:19:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE15-02937
| Final | 11/11/2015 | 11/12/2015 | 11/12/2015 9:14:23 AM | A | PASS |
|
|
Garage Code 2020E Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
|
ELE15-03653
| Electrical Rough-In | 11/10/2015 | 11/12/2015 | 11/12/2015 8:55:40 AM | A | PASS |
|
|
1 room Phone #: ###-#### Inspection requested via web by PAT MILLER Relocate fireplace in family room rough-in ok cover
|