Inspections for the day of: Thursday, November 12, 2015.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01056 Rough-In Permanent Service11/11/201511/12/201511/12/2015 4:35:21 PMPPASS
Conduit is replaced Phone #: ###-#### Inspection requested via web by John Harvey p/s u/g n ok
ELE15-03550 Final11/12/201511/12/201511/12/2015 4:12:24 PMPPASS
Please call for access info - Jonathan Phone #: ###-#### final ok
ELE15-03675 Electrical Rough-In11/11/201511/12/201511/12/2015 3:16:10 PMPPASS
floor heat inspection Phone #: ###-#### Inspection requested via web by Ryan Wake rough-in ok cover listed CSA floor heat
ELE15-02938 Conference11/12/201511/12/201511/12/2015 2:37:08 PMPDONE
Bob

Please call me when you get a chance about this
Mike
B ; B
###-#### Phone #: ###-#### Inspection requested via web by Mike Cole Contractor confirming required IMC raceways in roof decking
ELE15-03681 Electrical Rough-In11/12/201511/12/201511/12/2015 2:18:53 PMPPASS
underground only. Thanks Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
ELE15-03680 Electrical Rough-In11/12/201511/12/201511/12/2015 2:18:04 PMPPASS
underground only. thanks! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
ELE15-03678 Electrical Rough-In11/12/201511/12/201511/12/2015 2:17:20 PMPPASS
underground only. Thanks! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
ELE15-03676 Electrical Rough-In11/12/201511/12/201511/12/2015 2:13:13 PMPPASS
underground only thanks!!! Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover conduits underground
ELE15-03204 Final11/12/201511/12/201511/12/2015 1:48:47 PMPFAIL
Early afternoon if possible, please call Brad (###-####) 30 minutes ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard NEC 210.8 GFCI protection for kitchen counter receptacles
ELE15-03668 Temporary Service11/11/201511/12/201511/12/2015 1:32:13 PMAPASS
Phone #: ###-#### Inspection requested via web by Rhonda Yoast t/s o/h n ok
ELE15-03666 Final11/11/201511/12/201511/12/2015 1:23:50 PMAFAIL
Phone #: ###-#### Inspection requested via web by Kelly Felin Receptacle added on furnace for condensate pump in the garage requires GFCI protection NEC 210.8(A)(2)
ELE15-02808 Final11/11/201511/12/201511/12/2015 12:48:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson final ok
ELE15-03635 Conference11/9/201511/12/201511/12/2015 12:20:51 PMADONE
Joseph Phone #: ###-#### Discussed with homeowner electrical requirements for remodel and new addition
ELE15-03576 Permanent Service11/11/201511/12/201511/12/2015 11:45:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Atkins correction done,p/s u/g rec ok
ELE15-03595 Permanent Service11/10/201511/12/201511/12/2015 11:28:52 AMAPASS
If you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction done, p/s o/h rec ok
ELE15-03422 Electrical Rough-In11/10/201511/12/201511/12/2015 11:01:40 AMAPASS
Underground Inspection. Contact Travis Hust Phone #: ###-#### Inspection requested via web by Cathy Duchek correction done verified conduit depth, south parking lot, westside edge
ELE15-02881 Final11/12/201511/12/201511/12/2015 10:16:25 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
ELE15-02901 Final11/11/201511/12/201511/12/2015 10:04:54 AMAPASS
josh Phone #: ###-#### Inspection requested via web by kim grundhauser final ok
ELE15-02577 Final11/10/201511/12/201511/12/2015 9:49:36 AMAFAIL
Lockbox 1967, if you have any questions, please call Calvin at ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan No power to Master bath vanity receptacles
ELE15-03663 Temporary Service11/11/201511/12/201511/12/2015 9:20:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE15-03664 Temporary Service11/11/201511/12/201511/12/2015 9:19:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE15-02937 Final11/11/201511/12/201511/12/2015 9:14:23 AMAPASS
Garage Code 2020E Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
ELE15-03653 Electrical Rough-In11/10/201511/12/201511/12/2015 8:55:40 AMAPASS
1 room Phone #: ###-#### Inspection requested via web by PAT MILLER Relocate fireplace in family room rough-in ok cover