Inspections for the day of: Tuesday, November 13, 2012.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy Cobbley
TitleFIRE INSPECTOR
Phone #794-9483
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR12-00615 INSP-Final Inspection11/13/201211/13/201211/13/2012 4:00:29 PMPCANC
Overbooked. Brian will reschedule for tomorrow
FIR12-00615 INSP-Alarm Testing11/13/201211/13/201211/13/2012 3:58:24 PMPCANC
Overbooked. Brian will reschedule for tomorrow
BLD12-01069 FIRE-Final Inspection11/13/201211/13/201211/13/2012 3:56:55 PMPFAIL
See the city approved plans for the correction needed which include door hardware. Corrections and locations are marked in red.
BLD12-00739 FIRE-Final Inspection11/13/201211/13/201211/13/2012 3:53:16 PMPPASS
Life safety passed. Dave is going to remove the manual flush bolts on the interior double doors and replace with magnetic/friction stops.
FIR12-00496 INSP-Final Inspection11/13/201211/13/201211/13/2012 3:14:23 PMPPASS
Permit finaled. The rails for the overhead door have been removed.
BLD12-01789 FIRE-Conference11/13/201211/13/201211/13/2012 2:14:11 PMPDONE
With Scott Arellano's permission the stocking of the store is approved based on the existing fire sprinkler system in all areas to be stocked is functional and that the fire alarm permit has been submitted on. Also the contractor has agreed to supply security/fire watch for the "afterhours". Two rooms will not have the ceiling installed till a later date. These two rooms are electrical service rooms and it was agreed that there is to be no storage in these areas and that they are to be accessed for construction only.
FIR12-00494 INSP-Sprinkler Rough-in11/13/201211/13/201211/13/2012 2:11:02 PMPPASS
See the city approved plans for locations where piping above lay-in ceiling tiles can be covered.
FIR12-00287 INSP-Final Inspection11/12/201211/13/201211/13/2012 1:46:38 PMAPASS
Permit finaled. Earthquake bracing has been installed. I noted two missing retaining straps that Scott with Phoenix is going to install.
FIR12-00497 INSP-Final Inspection11/9/201211/13/201211/13/2012 12:48:33 PMAPASS
Permit finaled
BLD12-02878 FIRE-Final Inspection11/9/201211/13/201211/13/2012 11:55:56 AMAFAIL
Life safety will be ok to final when verification has been provided that the annual inspection for the existing fire sprinkler system has been performed. Jeremy with Boise Fire is currently working with the building owner on this issue.
FIR12-00318 INSP-Sprinkler Rough-in11/8/201211/13/201211/13/2012 11:10:32 AMACANC
Cancel per mike Phone #: ###-####
BLD12-02480 FIRE-Final Inspection11/9/201211/13/201211/13/2012 10:08:27 AMAPASS
Life safety passed
FIR12-00429 FIR-Aging Inspection11/13/201211/13/201211/13/2012 8:50:39 AM CANC
BLD12-02850 FIRE-Final Inspection11/9/201211/13/201211/13/2012 8:35:41 AMAPASS
Life safety passed. Owner was completing the removal of the storage off of the top shelves to meet the 18" rule.