ELE15-03677
| Final | 11/13/2015 | 11/13/2015 | 11/13/2015 1:54:14 PM | P | NR |
|
|
Please make late as possible to day. thank you Phone #: ###-#### Inspection requested via web by Randy Fletcher Working on conduit at time of inspection
|
ELE15-03677
| Permanent Service | 11/13/2015 | 11/13/2015 | 11/13/2015 1:31:24 PM | P | PASS |
|
|
Please make late as possible to day. thank you Phone #: ###-#### Inspection requested via web by Randy Fletcher Idaho Power owns and set service. Askided contractor to add or expose ground rod. Working on conduit at time of inspection will check back Monday for final. Approved for weather over weekend. p/s u/g rec ok
|
ELE15-03466
| Final | 11/13/2015 | 11/13/2015 | 11/13/2015 12:54:22 PM | P | CANC |
|
|
Stacy Phone #: ###-#### Needed permanent service inspection
|
ELE15-03466
| Permanent Service | 11/13/2015 | 11/13/2015 | 11/13/2015 12:54:05 PM | P | PASS |
|
|
Stacy Phone #: ###-#### 300.5(G)- Wher raceway contain #4 or larger conductors insulating bushings shall be installed. Nipples to interior panels on meter side. Will check next trip.
|
ELE15-03689
| Final | 11/12/2015 | 11/13/2015 | 11/13/2015 11:21:13 AM | A | PASS |
|
|
rough-in and final inspection for building F . lights ,gfi , panel .panel has power supplied from existing service.contact ####-#### Andy.phone ####-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski Rough in ok
|
ELE15-03689
| Final | 11/13/2015 | 11/13/2015 | 11/13/2015 11:19:55 AM | P | PASS |
|
|
rough-in and final inspection for building F . lights ,gfi , panel .panel has power supplied from existing service.contact ####-#### Andy.phone ####-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski Final ok
|
ELE15-03407
| Electrical Rough-In | 11/12/2015 | 11/13/2015 | 11/13/2015 10:47:36 AM | A | PASS |
|
|
Job Foreman: Jay Karel Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Disconnecting means and UL listing confirmed. Rough in ok
|
ELE15-03489
| Electrical Rough-In | 11/12/2015 | 11/13/2015 | 11/13/2015 10:26:44 AM | A | PASS |
|
|
Please inspect underground. Phone #: ###-#### Inspection requested via web by ERIC CENTERS Rough in ok cover
|
ELE15-02283
| Final | 11/12/2015 | 11/13/2015 | 11/13/2015 9:58:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Burke Final ok
|
ELE15-03457
| Final | 11/12/2015 | 11/13/2015 | 11/13/2015 9:11:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE15-03620
| Electrical Rough-In | 11/12/2015 | 11/13/2015 | 11/13/2015 8:47:53 AM | A | PASS |
|
|
Jimmy Phone #: ###-#### Discussed service change. Wall patches rough in ok cover
|