ELE15-03670
| Electrical Rough-In | 11/13/2015 | 11/13/2015 | 11/13/2015 1:58:22 PM | P | PASS |
|
|
Inspection for Idaho Power to restore power. Phone #: ###-#### Inspection requested via web by Randy Fletcher p/s o/h rec ok
|
ELE15-03641
| Permanent Service | 11/12/2015 | 11/13/2015 | 11/13/2015 12:55:57 PM | P | PASS |
|
|
would like call ahead; Mitch Phone #: ###-#### p/s o/h rec ok
|
ELE15-02355
| Final | 11/13/2015 | 11/13/2015 | 11/13/2015 12:25:58 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt 210.8(5)unfinished basements all 120V receptacles shall haveGFCI protection 210.12(a) bedrooms in a dwelling shall have AFCI protection(master bed has GFCI) 422.31 permanently installed appliances shall have means of lock out(dishwasher not set) 406.6 faceplates required (kitchen)
|
ELE15-03683
| Rough-In Permanent Service | 11/12/2015 | 11/13/2015 | 11/13/2015 11:10:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover p/s u/g n ok
|
ELE15-02280
| Final | 11/11/2015 | 11/13/2015 | 11/13/2015 10:31:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kendra Lanham bathroom and laundry final ok
|
ELE15-03690
| Electrical Rough-In | 11/12/2015 | 11/13/2015 | 11/13/2015 9:43:54 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terry Scott upstairs back beds and bath ok cover
|
ELE15-03391
| Final | 11/13/2015 | 11/13/2015 | 11/13/2015 9:32:28 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by John Edwards 210.8 receptacles in a kitchen shall be GFCI reading open ground aswell
|
ELE15-03175
| Final | 11/12/2015 | 11/13/2015 | 11/13/2015 9:18:11 AM | A | PASS |
|
|
Garage code 7606 Phone #: ###-#### Inspection requested via web by Charles Davis correction fixed final ok
|
ELE15-02563
| Final | 11/12/2015 | 11/13/2015 | 11/13/2015 9:02:31 AM | A | PASS |
|
|
Lock Box is located on front hose bib. Code is mjs Phone #: ###-#### Inspection requested via web by Eric Schroeder back bed and master bed final ok
|
ELE15-03687
| Temporary Service | 11/12/2015 | 11/13/2015 | 11/13/2015 9:02:27 AM | A | PASS |
|
|
Inspection requested via web by Brandon Hillman talked with contractor about changing out pole to a 4x4 p/s u/g n ok
|
ELE15-03687
| Final | 11/12/2015 | 11/13/2015 | 11/12/2015 6:01:58 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Brandon Hillman Inspection cancelled from web by: Brandon Hillman
|