MEC19-04088
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 3:41:39 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by David Compton - should nhave been R/I inspection
|
MEC19-04088
| Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 3:39:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Compton - fireplace R/I ok
|
MEC19-03516
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 3:26:59 PM | P | PASS |
|
|
garage code 3851 Phone #: ###-#### Inspection requested via web by Terek Worley- final ok
|
MEC19-05046
| Final | 11/13/2019 | 11/13/2019 | 11/13/2019 3:05:06 PM | P | PASS |
|
|
Homeowner Dave Chlebeck ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
|
MEC19-05119
| Final | 11/13/2019 | 11/13/2019 | 11/13/2019 2:44:51 PM | P | FAIL |
|
|
Please call ###-#### with eta to ensure someone is there today Phone #: ###-#### Inspection requested via web by Alyssa Cromwell- furnace coil co ok- need permit issued for water heater to final this permit out
|
MEC19-03225
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 2:28:18 PM | P | PASS |
|
|
Field super : Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-04888
| Final | 11/6/2019 | 11/13/2019 | 11/13/2019 1:42:09 PM | P | PASS |
|
|
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- 2 furnaces 3 coils 3 a/c ok
|
MEC19-05103
| Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 1:10:36 PM | P | PASS |
|
|
JON ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC19-04204
| Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 12:58:31 PM | P | NH |
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero- no access- all locked up
|
MEC19-05149
| Conference | 11/13/2019 | 11/13/2019 | 11/13/2019 12:47:53 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Greg Stahl- discussed exhaust fan installation for bathroom- will call in R/I inspection when ready
|
MEC19-03136
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 11:36:53 AM | P | FAIL |
|
|
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- need air balance report onsite- need to uv protection on lineset at a/c
|
MEC19-04621
| Rough-in | 11/11/2019 | 11/13/2019 | 11/13/2019 11:12:06 AM | A | FAIL |
|
|
Please call Blake with Altecca upon arriving or if you need any information. Phone #: ###-#### Inspection requested via web by Misty McNabb- need all supply, Return and outside air duct sealed- need to meet class 0 or 1 on flex duct off exhaust fan or run in rigid pipe or approved materials- schedule shows rigid pipe to slot diffusers need engineer approval on way installed or install per prints- does secondary drain pan meet plenum rated material 25/50 smoke/flame spread ?
|
MEC19-05029
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 10:55:32 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Doug Turner- condensate drains need ran in approved material- line set and mc cables need supported off ground
|
MEC19-04415
| Final | 11/7/2019 | 11/13/2019 | 11/13/2019 10:32:34 AM | A | PASS |
|
|
Please call prior to arrival. Janet ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
|
MEC19-05081
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 10:08:16 AM | A | PASS |
|
|
El-Ada #A-12927 S. Morgan Phone #: ###-#### Inspection requested via web by Loren Bailey- electric furnace coil only ok
|
MEC19-03383
| Final | 11/12/2019 | 11/13/2019 | 11/13/2019 9:57:10 AM | A | PASS |
|
|
Duct Blast Witness @ 10am. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass
|
MEC19-04687
| Pressure Test | 11/12/2019 | 11/13/2019 | 11/13/2019 9:38:55 AM | A | NR |
|
|
Ron Powell Phone #: ###-####- need 2 anadised riser installed plastic pipe can not be installed above ground and 30lb max gauge at 20psi for pressure test
|
MEC19-05132
| Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 9:03:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by brett hoopes- R/I ok- call in final when ready
|
MEC19-04893
| Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 8:32:09 AM | A | PASS |
|
|
JAMI 1-###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok- will look at mantel height at final
|
MEC18-04794
| Mec-Aging Inspection | 11/13/2019 | 11/13/2019 | 11/13/2019 8:02:11 AM | | CANC |
|
|
|
MEC18-04794
| DOC - Permit Expired | 11/13/2019 | 11/13/2019 | 11/13/2019 8:02:06 AM | A | PASS |
|
|
no calls- no activity- permit expired
|