Inspections for the day of: Wednesday, November 13, 2019.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04088 Final11/12/201911/13/201911/13/2019 3:41:39 PMPCANC
Phone #: ###-#### Inspection requested via web by David Compton - should nhave been R/I inspection
MEC19-04088 Rough-in11/13/201911/13/201911/13/2019 3:39:56 PMPPASS
Phone #: ###-#### Inspection requested via web by David Compton - fireplace R/I ok
MEC19-03516 Final11/12/201911/13/201911/13/2019 3:26:59 PMPPASS
garage code 3851 Phone #: ###-#### Inspection requested via web by Terek Worley- final ok
MEC19-05046 Final11/13/201911/13/201911/13/2019 3:05:06 PMPPASS
Homeowner Dave Chlebeck ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
MEC19-05119 Final11/13/201911/13/201911/13/2019 2:44:51 PMPFAIL
Please call ###-#### with eta to ensure someone is there today Phone #: ###-#### Inspection requested via web by Alyssa Cromwell- furnace coil co ok- need permit issued for water heater to final this permit out
MEC19-03225 Final11/12/201911/13/201911/13/2019 2:28:18 PMPPASS
Field super : Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC19-04888 Final11/6/201911/13/201911/13/2019 1:42:09 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- 2 furnaces 3 coils 3 a/c ok
MEC19-05103 Rough-in11/13/201911/13/201911/13/2019 1:10:36 PMPPASS
JON ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC19-04204 Rough-in11/12/201911/13/201911/13/2019 12:58:31 PMPNH
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero- no access- all locked up
MEC19-05149 Conference11/13/201911/13/201911/13/2019 12:47:53 PMPDONE
Phone #: ###-#### Inspection requested via web by Greg Stahl- discussed exhaust fan installation for bathroom- will call in R/I inspection when ready
MEC19-03136 Final11/12/201911/13/201911/13/2019 11:36:53 AMPFAIL
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- need air balance report onsite- need to uv protection on lineset at a/c
MEC19-04621 Rough-in11/11/201911/13/201911/13/2019 11:12:06 AMAFAIL
Please call Blake with Altecca upon arriving or if you need any information. Phone #: ###-#### Inspection requested via web by Misty McNabb- need all supply, Return and outside air duct sealed- need to meet class 0 or 1 on flex duct off exhaust fan or run in rigid pipe or approved materials- schedule shows rigid pipe to slot diffusers need engineer approval on way installed or install per prints- does secondary drain pan meet plenum rated material 25/50 smoke/flame spread ?
MEC19-05029 Final11/12/201911/13/201911/13/2019 10:55:32 AMAFAIL
Phone #: ###-#### Inspection requested via web by Doug Turner- condensate drains need ran in approved material- line set and mc cables need supported off ground
MEC19-04415 Final11/7/201911/13/201911/13/2019 10:32:34 AMAPASS
Please call prior to arrival. Janet ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC19-05081 Final11/12/201911/13/201911/13/2019 10:08:16 AMAPASS
El-Ada #A-12927 S. Morgan Phone #: ###-#### Inspection requested via web by Loren Bailey- electric furnace coil only ok
MEC19-03383 Final11/12/201911/13/201911/13/2019 9:57:10 AMAPASS
Duct Blast Witness @ 10am. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass
MEC19-04687 Pressure Test11/12/201911/13/201911/13/2019 9:38:55 AMANR
Ron Powell Phone #: ###-####- need 2 anadised riser installed plastic pipe can not be installed above ground and 30lb max gauge at 20psi for pressure test
MEC19-05132 Rough-in11/12/201911/13/201911/13/2019 9:03:06 AMAPASS
Phone #: ###-#### Inspection requested via web by brett hoopes- R/I ok- call in final when ready
MEC19-04893 Rough-in11/12/201911/13/201911/13/2019 8:32:09 AMAPASS
JAMI 1-###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok- will look at mantel height at final
MEC18-04794 Mec-Aging Inspection11/13/201911/13/201911/13/2019 8:02:11 AM CANC
MEC18-04794 DOC - Permit Expired11/13/201911/13/201911/13/2019 8:02:06 AMAPASS
no calls- no activity- permit expired