Inspections for the day of: Thursday, November 14, 2002.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-03527 Temporary Service11/13/200211/14/200211/14/2002 12:00:00 AMAPART
###-#### u/g for future t/s ok 11/14/2002 11:02:28 AM
ELE02-02360 Final11/13/200211/14/200211/14/2002 12:00:00 AMAPASS
###-#### ok 11/14/2002 12:33:03 PM
ELE01-03021 Final11/14/200211/14/200211/14/2002 12:00:00 AMPFAIL
###-#### russell job not ready partial correction posted 110.3(B) install grd bushings on all conduits entering non metallic boxes manufactrues instructionssupport all raceways and secure within 3 ft of boxes 314.25,250.110,406.5 grd all covers u/g jboxes 11/14/2002 6:18:01 PM
ELE02-03548 Rough-In Permanent Service11/14/200211/14/200211/14/2002 12:00:00 AMPFAIL
###-#### KEVIN cor. posted met with contractor 210.52 (A&B) outlet for wall spce over 6ft NE upstairs bedrm, and remove light fixture from small appliance circuit in din. rm replace 2 gang boxes with broken clamps 314.20 outside boxes shall be flush with siding, 250.6and 200.7 shall not use 2 wire romex for 3and 4 ways 11/14/2002 3:44:23 PM
ELE02-03550 Final11/14/200211/14/200211/14/2002 12:00:00 AMPPASS
###-#### ok 11/14/2002 4:29:06 PM
ELE02-01383 Final11/13/200211/14/200211/14/2002 12:00:00 AMPPASS
bruce ###-#### ok 11/14/2002 2:41:14 PM