Inspections for the day of: Thursday, November 14, 2002.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-03234 Permanent Service11/13/200211/14/200211/14/2002 12:00:00 AMAPASS
per pat at 8:30 -kenny; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
P/S O/H R ok 11/13/2002 10:24:38 AM
ELE02-03529 Temporary Service11/13/200211/14/200211/14/2002 12:00:00 AMAPASS
###-####
T/S O/H Ok
this is west main 11/14/2002 9:52:53 AM
ELE02-03530 Electrical Rough-In11/13/200211/14/200211/14/2002 12:00:00 AMAPASS
dawn- ###-####
ELE02-03497 Final11/13/200211/14/200211/14/2002 12:00:00 AMAFAIL
hot tub ###-####
250.142 Use of Grounded Circuit Conductor for Grounding Equipment.
(B) Load-Side Equipment.

680.22 Area Lighting, Receptacles, and Equipment.
(A) Receptacles.
Other receptacles shall be not less than 3.0 m (10 ft) from the inside walls of a pool.

(C) Switching Devices. Switching devices shall be located at least 1.5 m (5 ft) horizontally from the inside walls of a pool

680.26 Bonding.
(A) Performance. The bonding required by this section shall be installed to eliminate voltage gradients in the pool area as prescribed.
FPN:This section does not require that the 8 AWG or larger solid copper bonding conductor be extended or attached to any remote panelboard, service equipment, or any electrode.
(B) Bonded Parts. The parts specified in 680.26(B)(1) through (B)(5) shall be bonded together.
11/14/2002 9:18:38 AM
ELE02-03537 Final11/13/200211/14/200211/14/2002 12:00:00 AMPFAIL
###-#### or ###-####
wires over hot tub 11/14/2002 4:59:40 PM
ELE02-03542 Electrical Rough-In11/13/200211/14/200211/14/2002 12:00:00 AMPPASS
rick ###-####
ELE02-03543 Permanent Service11/14/200211/14/200211/14/2002 12:00:00 AMPNR
###-####
ELE02-03546 Rough-In Permanent Service11/14/200211/14/200211/14/2002 12:00:00 AMPFAIL
###-####- chris
mounting of NM boxes 11/14/2002 2:41:10 PM