ELE02-03234
| Permanent Service | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | A | PASS |
|
|
per pat at 8:30 -kenny; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
P/S O/H R ok 11/13/2002 10:24:38 AM
|
ELE02-03529
| Temporary Service | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | A | PASS |
|
|
###-####
T/S O/H Ok
this is west main 11/14/2002 9:52:53 AM
|
ELE02-03530
| Electrical Rough-In | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | A | PASS |
|
|
dawn- ###-####
|
ELE02-03497
| Final | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | A | FAIL |
|
|
hot tub ###-####
250.142 Use of Grounded Circuit Conductor for Grounding Equipment.
(B) Load-Side Equipment.
680.22 Area Lighting, Receptacles, and Equipment.
(A) Receptacles.
Other receptacles shall be not less than 3.0 m (10 ft) from the inside walls of a pool.
(C) Switching Devices. Switching devices shall be located at least 1.5 m (5 ft) horizontally from the inside walls of a pool
680.26 Bonding.
(A) Performance. The bonding required by this section shall be installed to eliminate voltage gradients in the pool area as prescribed.
FPN:This section does not require that the 8 AWG or larger solid copper bonding conductor be extended or attached to any remote panelboard, service equipment, or any electrode.
(B) Bonded Parts. The parts specified in 680.26(B)(1) through (B)(5) shall be bonded together.
11/14/2002 9:18:38 AM
|
ELE02-03537
| Final | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | P | FAIL |
|
|
###-#### or ###-####
wires over hot tub 11/14/2002 4:59:40 PM
|
ELE02-03542
| Electrical Rough-In | 11/13/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | P | PASS |
|
|
rick ###-####
|
ELE02-03543
| Permanent Service | 11/14/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | P | NR |
|
|
###-####
|
ELE02-03546
| Rough-In Permanent Service | 11/14/2002 | 11/14/2002 | 11/14/2002 12:00:00 AM | P | FAIL |
|
|
###-####- chris
mounting of NM boxes 11/14/2002 2:41:10 PM
|