ELE05-04121
| Rough-In Permanent Service | 11/14/2005 | 11/14/2005 | 11/14/2005 4:55:38 PM | P | CANC |
|
|
chris ###-#### inspection came in as another address, talked to contr and office both. Will need to do in am with proper address
|
ELE05-04112
| Rough-In Permanent Service | 11/14/2005 | 11/14/2005 | 11/14/2005 4:53:45 PM | P | FAIL |
|
|
brian ###-#### called contr, left corr notice, 300.4(A)&(D) 1 1/4" shall be maintained for bored holes and nm cable shall be from edge of framing member, 800.133(A)(1) comm cable shall not be run with class 1 wiring,110.12(A) there shall be no open wiring holes in boxes, 314.20 boxes shall be flush with combustibloe material (out back recpt), BCC job id sticker shall be posted
|
ELE05-02341
| Final | 11/14/2005 | 11/14/2005 | 11/14/2005 4:48:23 PM | P | PASS |
|
|
earl call 1/2 before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--pending bld fn met owner, told to provide gfci in garage, w/p recpt covers outside and flex to range hood. ok to final
|
ELE05-04098
| Electrical Rough-In | 11/10/2005 | 11/14/2005 | 11/14/2005 4:43:40 PM | P | CANC |
|
|
tony ###-#### see conf
|
ELE05-03276
| Electrical Rough-In | 11/14/2005 | 11/14/2005 | 11/14/2005 4:41:51 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Barbara Moore told elect to strap emt a couple places, ric front soffit only ok
|
ELE05-04036
| Temporary Service | 11/14/2005 | 11/14/2005 | 11/14/2005 4:39:20 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/14/2005 at 10:20:24 AM. Contact: ###-####. called contr, left message, left corr notice, 110.12(C) there shall be no broken parts(50 A rcpt)
|
ELE05-03661
| Electrical Rough-In | 11/14/2005 | 11/14/2005 | 11/14/2005 3:50:42 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 11/14/2005 at 8:09:32 AM. Contact: ###-####. so 1/2 clg ok to cover
|
ELE05-04064
| Temporary Service | 11/14/2005 | 11/14/2005 | 11/14/2005 2:17:03 PM | P | PASS |
|
|
michael; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa t/s u/g n ok
|
ELE05-03088
| Final | 11/14/2005 | 11/14/2005 | 11/14/2005 1:59:32 PM | P | PASS |
|
|
Please final Edwards Theatre signs Internet Inspection Request from: Radon Elaina ok to final
|
ELE05-03852
| Final | 11/14/2005 | 11/14/2005 | 11/14/2005 1:44:52 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2005 at 8:08:39 AM. signed card, ok to fnali
|
ELE05-03871
| Final | 11/14/2005 | 11/14/2005 | 11/14/2005 1:41:50 PM | P | PASS |
|
|
josh; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to final
|
ELE05-04117
| Electrical Rough-In | 11/14/2005 | 11/14/2005 | 11/14/2005 10:53:32 AM | P | PASS |
|
|
brian ###-#### walls only ok to cover
|
ELE05-03522
| Final | 11/14/2005 | 11/14/2005 | 11/14/2005 10:52:50 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2005 at 7:38:18 AM. Contact: ###-####. signed occ card, ok to final
|
ELE05-04077
| Temporary Service | 11/10/2005 | 11/14/2005 | 11/14/2005 10:51:33 AM | A | PASS |
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/s u/g n ok
|
ELE05-03620
| Rough-In Permanent Service | 11/10/2005 | 11/14/2005 | 11/14/2005 10:07:56 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called contr, left corr notice,334.30 nm cable shall be stapled wthin 12" of box,314.17(C) nm shall be stapled within 8" of box,300.4(A)&(D) bored holes and cable shall be 1 1/4" from edge of framing member,800.133(A) comm cable shall not be run with power wiring, 312.5 abrasion protection shall be provided for conductors entering enclosures.
|
ELE05-02783
| Permanent Service | 11/10/2005 | 11/14/2005 | 11/14/2005 9:32:01 AM | A | FAIL |
|
|
richard ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles told owner, left corr notice,250.24(B) bonding jumper shall be installed from gnded conductor to equip gnd
|
ELE05-04100
| Rough-In Permanent Service | 11/11/2005 | 11/14/2005 | 11/14/2005 8:47:16 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ric ok p/s u/g n ok
|
ELE05-03533
| Electrical Rough-In | 11/10/2005 | 11/14/2005 | 11/14/2005 8:30:08 AM | A | PART |
|
|
request ealy as possible//mike; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to pour 7 pole bases
|
ELE05-04096
| Rough-In Permanent Service | 11/10/2005 | 11/14/2005 | 11/14/2005 8:24:20 AM | A | PASS |
|
|
ron ###-#### ric ok p/s u/g n ok
|
ELE05-04098
| Conference | 11/14/2005 | 11/14/2005 | 11/14/2005 12:00:00 AM | P | DONE |
|
|
tony ###-#### too many items to write, so made conf, not ri
|