Inspections for the day of: Monday, November 14, 2005.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS05-00200 BLD-Final11/14/200511/14/200511/14/2005 3:57:08 PMPPASS
bob; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD05-01767 BLD-Final11/14/200511/14/200511/14/2005 3:56:11 PMPCANC
bill; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. Life/safety failed.
BLD05-02919 BLD-Footing11/14/200511/14/200511/14/2005 2:33:20 PMPPART
###-#### larry
BLD05-02624 BLD-Framing/Rough-in11/14/200511/14/200511/14/2005 1:40:24 PMPNH
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. No access.
BLD05-01926 BLD-Final11/10/200511/14/200511/14/2005 12:39:28 PMPCANC
Scheduled by a contractor via Hello! on 11/10/2005 at 8:22:34 AM. Contact: ###-####.
BLD05-02305 BLD-Footing11/14/200511/14/200511/14/2005 12:39:05 PMPPASS
ryan ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD05-02306 BLD-Footing11/14/200511/14/200511/14/2005 12:38:48 PMPPASS
ryan ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD05-02581 BLD-Framing/Rough-in11/10/200511/14/200511/14/2005 11:26:35 AMAPASS
bruce; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD05-01150 BLD-Framing/Rough-in11/10/200511/14/200511/14/2005 10:57:09 AMAPASS
Scheduled by a contractor via Hello! on 11/10/2005 at 4:08:20 PM. Contact: ###-####. Hangars were nailed off. Reviewed RFI From engineer detailing welded connection at column to beam connection.
BLD05-02766 BLD-Footing11/10/200511/14/200511/14/2005 10:23:23 AMAPASS
clint; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
BLD05-01226 BLD-Framing/Rough-in11/10/200511/14/200511/14/2005 10:14:24 AMAFAIL
chris; Phone #: ###-#### Note: Please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles. Provide tall wall engineering. Provide additional 2x6 studs at CG truss bearing. Provide strapping at top plates at bearing walls in basement. (either side of stairway) Complete lateral bracing at AR2 and CG trusses. Provide HGUS26-2 hangars at A3B and FG trusses as noted on truss engineering.
BLD05-02225 BLD-Foundation11/11/200511/14/200511/14/2005 9:04:51 AMAPASS
Scheduled by a contractor via Hello! on 11/11/2005 at 2:18:41 PM. Contact: ###-####.
BLD05-00574 BLD-Other11/10/200511/14/200511/14/2005 9:01:18 AMACANC
natt Note: racking; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Notified by permit desk of cancellation.
MIS05-00200 DOC - Permit Finaled11/14/200511/14/200511/14/2005 12:00:00 AMPPASS