MIS05-00200
| BLD-Final | 11/14/2005 | 11/14/2005 | 11/14/2005 3:57:08 PM | P | PASS |
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-01767
| BLD-Final | 11/14/2005 | 11/14/2005 | 11/14/2005 3:56:11 PM | P | CANC |
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. Life/safety failed.
|
BLD05-02919
| BLD-Footing | 11/14/2005 | 11/14/2005 | 11/14/2005 2:33:20 PM | P | PART |
|
|
###-#### larry
|
BLD05-02624
| BLD-Framing/Rough-in | 11/14/2005 | 11/14/2005 | 11/14/2005 1:40:24 PM | P | NH |
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. No access.
|
BLD05-01926
| BLD-Final | 11/10/2005 | 11/14/2005 | 11/14/2005 12:39:28 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 11/10/2005 at 8:22:34 AM. Contact: ###-####.
|
BLD05-02305
| BLD-Footing | 11/14/2005 | 11/14/2005 | 11/14/2005 12:39:05 PM | P | PASS |
|
|
ryan ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD05-02306
| BLD-Footing | 11/14/2005 | 11/14/2005 | 11/14/2005 12:38:48 PM | P | PASS |
|
|
ryan ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD05-02581
| BLD-Framing/Rough-in | 11/10/2005 | 11/14/2005 | 11/14/2005 11:26:35 AM | A | PASS |
|
|
bruce; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-01150
| BLD-Framing/Rough-in | 11/10/2005 | 11/14/2005 | 11/14/2005 10:57:09 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/10/2005 at 4:08:20 PM. Contact: ###-####. Hangars were nailed off. Reviewed RFI From engineer detailing welded connection at column to beam connection.
|
BLD05-02766
| BLD-Footing | 11/10/2005 | 11/14/2005 | 11/14/2005 10:23:23 AM | A | PASS |
|
|
clint; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD05-01226
| BLD-Framing/Rough-in | 11/10/2005 | 11/14/2005 | 11/14/2005 10:14:24 AM | A | FAIL |
|
|
chris; Phone #: ###-#### Note: Please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles. Provide tall wall engineering. Provide additional 2x6 studs at CG truss bearing. Provide strapping at top plates at bearing walls in basement. (either side of stairway) Complete lateral bracing at AR2 and CG trusses. Provide HGUS26-2 hangars at A3B and FG trusses as noted on truss engineering.
|
BLD05-02225
| BLD-Foundation | 11/11/2005 | 11/14/2005 | 11/14/2005 9:04:51 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/11/2005 at 2:18:41 PM. Contact: ###-####.
|
BLD05-00574
| BLD-Other | 11/10/2005 | 11/14/2005 | 11/14/2005 9:01:18 AM | A | CANC |
|
|
natt Note: racking; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Notified by permit desk of cancellation.
|
MIS05-00200
| DOC - Permit Finaled | 11/14/2005 | 11/14/2005 | 11/14/2005 12:00:00 AM | P | PASS |
|
|
|