Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03794 Electrical Rough-In11/14/200711/14/200711/14/2007 4:17:47 PMPNR
jesse Phone #: ###-#### called needs to increase p/s size or install gas range owner will tell contr when she decides
ELE07-03803 Permanent Service11/14/200711/14/200711/14/2007 3:35:05 PMPPASS
Late in afternoon if possible. thank you. Randy ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok needs concrete encased electrode installed before final p/s o/h rec. ok
ELE07-01689 Electrical Rough-In11/14/200711/14/200711/14/2007 2:32:49 PMPPART
troy Phone #: ###-#### Note: please call 1/2 hr prior to inspection addition and electrode ok
ELE07-03792 Final11/14/200711/14/200711/14/2007 1:30:31 PMPNR
Darren Phone #: ###-#### see added p/s, note needs machine thread screw for grd at pole 250.8, 110.3(B) and 314.3 needs bond bushing for emt in plastic enclosure
ELE07-03792 Permanent Service11/14/200711/14/200711/14/2007 1:28:35 PMPPASS
Darren Phone #: ###-#### p/s o/h new ok
ELE99-03913 Final11/14/200711/14/200711/14/2007 1:27:19 PMPPASS
Darren Phone #: ###-#### ok see new ele permit
ELE07-03679 Final11/13/200711/14/200711/14/2007 11:24:24 AMAPASS
Pat Gill Phone #: ###-#### Internet Inspection Request from: Debby Ellis
ok card signed
ELE07-03757 Electrical Rough-In11/13/200711/14/200711/14/2007 10:31:02 AMAPART
john - bonding Phone #: ###-#### E grid ok
and bonding for other metal ok
ELE07-02309 Final11/13/200711/14/200711/14/2007 10:04:38 AMAPART
Roger Reynolds is contact ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis t/o ok card signed
ELE07-03514 Electrical Rough-In11/14/200711/14/200711/14/2007 8:35:54 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman corr called 410.8 MB closet, 300.4(A)(1)&(D), 334.23, 210.52(A) spacing top of stairs stub wall