Inspections for the day of: Monday, November 14, 2011.
Number of inspections: 15
Percentage of inspections complete: 93 %
Percentage of inspections not complete: 7 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC11-00804 Site Preparation11/7/201111/7/2011   
ELE10-02255 ELE-Aging Inspection11/14/201111/14/201111/21/2011 2:05:53 PM DONE
Electrical contractor will check out job, see if it ready for final
ELE10-02349 ELE-Aging Inspection11/14/201111/14/201111/18/2011 10:19:53 AM DONE
electrical contractor checking into jobs progress
ELE11-02162 Final11/14/201111/14/201111/14/2011 4:34:10 PMPPASS
Final ok Electrical contractor will label space number on service by 11/16/2011 or final will be revoked
ELE11-02542 Final11/14/201111/14/201111/14/2011 4:05:52 PMPNH
Owner contact is Ms. Hollis. She is hoping for a 3:30 - 4:00 pm inspection. If this won''t work. Call Bill Hines for access. ###-####. Please allow a few minutes for travel to the site. Phone #: ###-#### >> Inspection requested via web by Clint Tate
ELE11-01967 Final11/14/201111/14/201111/14/2011 3:00:56 PMPPASS
kevin Phone #: ###-#### final ok
ELE11-02241 Electrical Rough-In11/10/201111/14/201111/14/2011 2:06:47 PMPFAIL
lee Phone #: ###-#### NEC 300.4 Where bored holes are less than 1 1/4 from edge of framing member shall use nail plates. NEC 300.4(A) shall staple romex at least 1 1/4 from framing member. NEC 334.30 Shall staple NM cable within 12" of box
ELE11-02304 Electrical Rough-In11/14/201111/14/201111/14/2011 1:06:02 PMPPASS
dennis Phone #: ###-#### rough-in ok cover teller drive through ceiling grid
ELE11-02541 Rough-In Permanent Service11/14/201111/14/201111/14/2011 12:48:41 PMPPASS
THANKS, BILL Phone #: ###-#### >> Inspection requested via web by Bob Glenn rough-in p/s u/g ok
ELE11-02553 Electrical Rough-In11/10/201111/14/201111/14/2011 10:08:52 AMAPASS
rough in ready for cover please call will meet to walk through thank you Phone #: ###-#### >> Inspection requested via web by Brad Baker rough-in ok cover
ELE11-02402 Final11/11/201111/14/201111/14/2011 9:21:23 AMAPASS
Enter off of 14th and go throught the side gate. You will see a door leading to the basement. Phone #: ###-#### >> Inspection requested via web by Brad Girard final ok
ELE11-02501 Electrical Rough-In11/10/201111/14/201111/14/2011 9:20:21 AMAPASS
Phone #: ###-#### >> Inspection requested via web by JENNY EMEL rough-in ok cover walls
ELE11-00409 Final11/10/201111/14/201111/14/2011 8:54:43 AMAPASS
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden fina;l ok
ELE11-01571 Final11/10/201111/14/201111/14/2011 8:29:37 AMAPASS
jentry Phone #: ###-#### final ok
ELE11-02049 Conference11/14/201111/14/201111/14/2011 12:00:00 AMPCANC
Justin Phone #: ###-####