Inspections for the day of: Monday, November 14, 2016.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-02986 Final11/10/201611/14/201611/14/2016 3:02:08 PMPPASS
Call if necessary. Phone #: ###-#### Inspection requested via web by Samatha Solberg Final ok
ELE16-02180 Final11/11/201611/14/201611/14/2016 2:16:05 PMPPASS
Call Mitch 30 minutes prior. Phone #: ###-#### Inspection requested via web by Mitch Whited Final ok
ELE16-02247 Electrical Rough-In11/11/201611/14/201611/14/2016 1:07:41 PMAPASS
Patio cover. Walk around east side to back yard. Phone #: ###-#### Inspection requested via web by mike brown
Back patio rough in ok cover
ELE16-03673 Rough-In Permanent Service11/14/201611/14/201611/14/2016 12:40:57 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey
110.3- Service feeders not installed.
210.52(A)- Receptacle outlet shall be installed for 6' wall space to right of fireplace.
210.52(B)- Pantry counter top shall have receptacle outlet layout same as kitchen.
210.52(D)- Master bath vanity receptacle is placed behind wall and will ot be in place to serve basin.
250.110- Equipment ground shall be connected in temp connection of furnaces and abrasion protection shall be present as per 300.4.
IBC- Boxes for soffit cans shall be down to soffit material for air seal.
590.6- 50 amp GFCI receptacle in temp pole will not trip.
ELE16-03673 Final11/10/201611/14/201611/14/2016 12:34:49 PMACANC
Phone #: ###-#### Inspection requested via web by Neal Rumsey
Needed rough in and permanant service.
ELE16-03665 Electrical Rough-In11/10/201611/14/201611/14/2016 11:27:19 AMAPASS
Drive by to verify dry sheeting on roof complete for wiring installed front and rear patios. Contact Bob ###-####
Job dry sheeting complete. Soffits ok
ELE16-03547 Rough-In Permanent Service11/10/201611/14/201611/14/2016 9:31:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok
ELE15-02641 Final11/10/201611/14/201611/14/2016 8:44:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
No card posted.
Final ok
ELE16-03489 Final11/12/201611/14/201611/14/2016 8:44:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
Final ok
ELE16-03489 Electrical Rough-In11/12/201611/14/201611/14/2016 8:43:52 AMAPASS
ceiling grid Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
Grid rough in ok cover