ELE13-02671
| ELE-Aging Inspection | 11/14/2017 | 11/14/2017 | 11/20/2017 10:35:27 AM | | FAIL |
|
|
No responce to notice, No responce to message.
|
ELE17-03421
| Final | 11/7/2017 | 11/14/2017 | 11/14/2017 2:16:00 PM | P | NR |
|
|
Brandy Phone #: ###-#### Not ready
|
ELE17-03421
| Electrical Rough-In | 11/14/2017 | 11/14/2017 | 11/14/2017 2:15:29 PM | P | PASS |
|
|
Brandy Phone #: ###-#### Underground between House and garage was not inspected. Ends of runs were open to verify depth. Informed office of inspection requiements. UL listing verified. rough in ok
|
ELE17-02673
| Electrical Rough-In | 11/14/2017 | 11/14/2017 | 11/14/2017 1:13:48 PM | P | PASS |
|
|
Partial wall inspection Phone #: ###-#### Inspection requested via web by Stephanie Huston North Exterior wall behind main service only ok to cover
|
ELE17-02504
| Final | 11/14/2017 | 11/14/2017 | 11/14/2017 12:47:48 PM | P | PASS |
|
|
Ron Phone #: ###-#### corrections made final ok
|
ELE17-01217
| Final | 11/13/2017 | 11/14/2017 | 11/14/2017 11:32:37 AM | A | PASS |
|
|
Please call Paul with questions ###-#### Homeowner John ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer Kitchen only final ok
|
ELE17-03828
| Final | 11/13/2017 | 11/14/2017 | 11/14/2017 11:31:56 AM | A | FAIL |
|
|
Please contact Eva, the homeowner for access at ###-#### Phone #: ###-#### Inspection requested via web by Kerri Hamilton 690.13B PV systam disc shall be marked.690.31G PV system circuits shall be ran in metal raceway. 690.31G3 690.31G4. Raceway shall be marked every 10ft and shall use listed labeling. 690.43. PV equipment shall be bonded. Idaho power disc shall be "Knife Switch" style with external handle and shall be lockable.
|
ELE16-00900
| Final | 11/7/2017 | 11/14/2017 | 11/14/2017 10:09:55 AM | A | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Sign only final ok
|
ELE16-00900
| Electrical Rough-In | 11/14/2017 | 11/14/2017 | 11/14/2017 10:09:39 AM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle sign rough in ok
|
ELE16-00526
| Final | 11/7/2017 | 11/14/2017 | 11/14/2017 10:09:12 AM | A | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Sign only final ok
|
ELE16-00526
| Electrical Rough-In | 11/14/2017 | 11/14/2017 | 11/14/2017 10:08:46 AM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Sign rough in ok
|
ELE17-03752
| Temporary Service | 11/13/2017 | 11/14/2017 | 11/14/2017 10:08:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE17-03751
| Temporary Service | 11/13/2017 | 11/14/2017 | 11/14/2017 10:07:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE17-02662
| Electrical Rough-In | 11/13/2017 | 11/14/2017 | 11/14/2017 9:35:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by A.M.E. Office Walls only Office area only ok to cover
|