ELE02-02528
| Final | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2002 at 10:43:10. Contact: ###-####. ok 11/15/2002 10:36:15 AM
|
ELE02-02641
| Final | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/14/2002 at 12:03:52. Contact: .
no final till homeowner secures electrical permit for work on garage PM#bld02-01813 per note on structrual permit 11/15/2002 1:51:26 PM
|
ELE02-03472
| Final | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | CANC |
|
|
###-#### GARY called could not hear message called orther number no contact, cor posted 250.53 (B) grd rod not 6ft apart,250.92 (A)(3) bond both ends of nipple between meter and p/s when GEC passes through it. 312.3 service panel shall be flush with finish surface and cover fit tight to panel,250.52 or 104 grd within 5 ft or bond 11/15/2002 2:26:30 PM
|
ELE02-03322
| Final | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | CANC |
|
|
dawn; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie see added r/i 11/15/2002 12:39:10 PM
|
ELE02-03176
| Final | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/15/2002 at 07:27:46. Contact: ###-####. cor. posted met with contractor 314.20 250.146(A) boxes with raised covers, 300.11 use own support wires too support raceways in grid ceiling, 300.7 seal conduits entering cooler,, 250.6 arrange wires in conduits to contacter to prevent objectionable currents, 110.12(A) seal unused KOs cor. posted to BLD02-02261 support low voltage cables laying on grid ceiling $42.00 reinspection fee due 11/15/2002 11:42:55 AM
|
ELE02-03322
| Electrical Rough-In | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
r/i for garage ok
|
ELE02-03472
| Permanent Service | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | FAIL |
|
|
see final inspection request for correction info
|
ELE02-01024
| Final | 11/12/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | CANC |
|
|
###-#### CHRISTI called no access person at house did not have key,, they will call for reinspection at a later date 11/15/2002 4:49:45 PM
|
ELE02-03536
| Electrical Rough-In | 11/13/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PART |
|
|
STEVE ###-#### OR CELL # ###-#### CONF ONLY ok 11/15/2002 3:36:53 PM
|
ELE02-03522
| Electrical Rough-In | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
###-#### ok still needs outlet too serve din. rm wall for proper spacing , will install at time of trim out 11/15/2002 2:50:35 PM
|
ELE02-01274
| Electrical Rough-In | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PART |
|
|
CONFERENCE FOR EXTENSION ONLY PLEASE CALL ###-#### ALLISON ok 11/15/2002 5:25:55 PM
|
ELE02-03558
| Permanent Service | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
dawn ###-#### p/s u/g rec. for meter ok 11/15/2002 4:11:53 PM
|