BLD02-01862
| BLD-Final | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
###-#### ok for perm occ 11/15/2002 10:31:09 AM
|
BLD02-02159
| BLD-Wall cover | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2002 at 11:26:14. Contact: ###-####. ok to cover 11/15/2002 9:19:46 AM
|
BLD02-02670
| BLD-Footing | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2002 at 16:04:52. Contact: ###-####.
|
BLD02-02670
| BLD-Foundation | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/14/2002 at 16:05:25. Contact: ###-####. work in progress rebar is in forms 50% complete 11/15/2002 11:05:51 AM
|
BLD02-01474
| BLD-Energy code compliance | 11/14/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
ok to cover have letter from briggs stating that they have reviewed the steel and beam framing and approved 11/15/2002 9:52:36 AM
|
BLD02-01693
| BLD-Final | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/15/2002 at 05:56:56. Contact: . c.c # 22607 issued 11/15/2002 9:17:03 AM
|
MEC02-02583
| Final | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
|
MEC02-02633
| Final | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | A | PASS |
|
|
|
BLD02-02246
| BLD-Footing | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PART |
|
|
ready at 4 ###-#### builder needs to resubmit plans for new engineering has changed bearing walls and hold down locations told crew they could pour but at thier own risk 11/15/2002 2:10:11 PM
|
MEC02-02595
| Final | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/15/2002 at 11:16:47. Contact: ###-####.
|
MEC02-03365
| Pressure Test | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
|
BLD02-02643
| BLD-Foundation | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/15/2002 at 07:22:41. Contact: ###-####.
|
MEC02-03365
| Rough-in | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | PASS |
|
|
kim ###-####
|
MEC02-03087
| Rough-in | 11/15/2002 | 11/15/2002 | 11/15/2002 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/15/2002 at 08:40:08. Contact: ###-####. crew used wrong gaurd plates for gas piping still need 6'' of clearance from singal wall vent pipe to side wall need to strape b-vent in atticc so it cant move back on to flix duct also return air duct is now been pinched reducing size so clearance can be maintained for bvent 11/15/2002 2:35:10 PM
|