BLD06-02226
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 5:34:37 PM | P | PASS |
|
|
Life safety finaled
|
BLD06-02225
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 5:34:02 PM | P | PASS |
|
|
Life safety finaled
|
FIR06-00641
| INSP-Sprinkler Rough-in/Hydro | 11/14/2006 | 11/15/2006 | 11/15/2006 5:32:51 PM | P | PASS |
|
|
Underground hydro test passed.
|
FIR06-00740
| INSP-Sprinkler Rough-in/Hydro | 11/15/2006 | 11/15/2006 | 11/15/2006 3:50:38 PM | P | PASS |
|
|
Sprinkler piping is ok to cover
|
FIR06-00751
| INSP-Final Inspection | 11/15/2006 | 11/15/2006 | 11/15/2006 3:14:39 PM | P | CANC |
|
|
Grant will reschedule for tomorrow
|
BLD06-01581
| FIRE-Final Inspection | 11/15/2006 | 11/15/2006 | 11/15/2006 3:14:06 PM | P | FAIL |
|
|
The emergency light in the main lobby on the left hand wall as you walk in does not work. All other items are ok.
|
FIR06-00802
| INSP-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 2:41:07 PM | A | PASS |
|
|
Permit finaled
|
FIR05-00582
| INSP-Sprinkler Rough-in | 11/15/2006 | 11/15/2006 | 11/15/2006 2:06:44 PM | P | PASS |
|
|
Pendant heads in the pharmacy area, as installed in the ceiling tile have passed. Waiting on alarms and life safety.
|
BLD06-01831
| FIRE-Conference | 11/14/2006 | 11/15/2006 | 11/15/2006 1:52:12 PM | P | PASS |
|
|
The contractor had a question about a pipe penatration through a rated wall
|
FIR06-00662
| INSP-Sprinkler Rough-in/Hydro | 11/14/2006 | 11/15/2006 | 11/15/2006 1:33:08 PM | A | PASS |
|
|
Underground flush passed.
|
BLD06-01566
| FIRE-Final Inspection | 11/13/2006 | 11/15/2006 | 11/15/2006 1:32:42 PM | A | CANC |
|
|
Contractor will reschedule for friday.
|
FIR06-00498
| INSP-Sprinkler Rough-in/Hydro | 11/14/2006 | 11/15/2006 | 11/15/2006 1:11:52 PM | A | PASS |
|
|
Underground hydro test passed. The end of the test was witnessed by Mike Clay the general contractors representative.
|
FIR06-00500
| INSP-Sprinkler Rough-in/Hydro | 11/14/2006 | 11/15/2006 | 11/15/2006 1:11:29 PM | A | PASS |
|
|
Underground hydro test passed. The end of the test was witnessed by Mike Clay the general contractors representative.
|
BLD06-01779
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 12:00:17 PM | A | FAIL |
|
|
Provide indicator at the main exit and either remove the non required exit discharge lights or provide listed devices for the damp and cold temperatures.
|
BLD06-02380
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 11:57:59 AM | P | CANC |
|
|
To be rescheduled for tomorrow
|
FIR06-00826
| INSP-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 11:57:43 AM | P | CANC |
|
|
To be rescheduled for tomorrow
|
BLD06-02487
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 11:48:33 AM | A | PASS |
|
|
Life safety finaled
|
FIR06-00808
| INSP-Final Inspection | 11/15/2006 | 11/15/2006 | 11/15/2006 11:48:15 AM | P | PASS |
|
|
permit finaled
|
FIR06-00320
| INSP-Final Inspection | 11/13/2006 | 11/15/2006 | 11/15/2006 11:16:56 AM | A | FAIL |
|
|
Contractor was not ready for flush. The only items I inspected was the sprinkler heads. The head in the utility room is blocked by the light fixture. Many heads have been added. I told brian that he needs to provide as-builts to the returning inspector
|
FIR06-00817
| INSP-Final Inspection | 11/9/2006 | 11/15/2006 | 11/15/2006 9:38:59 AM | A | PASS |
|
|
permit finaled
|
BLD06-02364
| FIRE-Final Inspection | 11/14/2006 | 11/15/2006 | 11/15/2006 9:37:43 AM | A | PASS |
|
|
life safety finaled
|
FIR06-00612
| INSP-Alarm Testing | 11/14/2006 | 11/15/2006 | 11/15/2006 9:37:27 AM | A | PASS |
|
|
permit finaled
|
FIR06-00309
| INSP-Final Inspection | 11/9/2006 | 11/15/2006 | 11/15/2006 9:36:07 AM | A | FAIL |
|
|
Missing the 30cd a/v in the storage room as shown on the revision 2 plans.
|
BLD06-01120
| FIRE-Final Inspection | 11/9/2006 | 11/15/2006 | 11/15/2006 9:35:33 AM | A | FAIL |
|
|
No life safety performed since the fire alarm failed
|
FIR06-00738
| INSP-Final Inspection | 11/14/2006 | 11/15/2006 | 11/14/2006 2:01:34 PM | A | FAIL |
|
|
A retaining strap is needed on the sidebeam bracket in the wormens sauna and the hanger in the mens sauna needs to be taken to the structure and provided with a retaining strap.
|