Inspections for the day of: Thursday, November 15, 2007.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02763 ELE-Aging Inspection11/15/200711/15/200711/16/2007 10:21:57 AM DONE
called ,left message to call for inspection
ELE07-03252 Electrical Rough-In11/15/200711/15/200711/15/2007 4:52:41 PMPFAIL
chewey Phone #: ###-#### met owner, reviewed following: left correction notice,NEC 110.11 there shall be no agents that will deteriorate conductors, 250.86 shall ground metal boxes with approved means, 300.14 shall provide 6" free conductor length in boxes, 110.12(C) there shall be no broken boxes, 210.52(A)(1) no point along floor line shall be over 6' from a receptacle, 210.52(A)(2) wall space is 2' along floor line and shall have receptacle installed, 314.17(C) nm cable shall be stapled within 8" of 2x4 box, 210.12(B) bedrooms shall have listed arc fault circuit interrupters installed, 210.52(C)(1) countertops shall have receptacles installed within 2' of sink edge
ELE07-03614 Electrical Rough-In11/14/200711/15/200711/15/2007 3:42:40 PMPPASS
harry Phone #: ###-#### ok to cover u/g house to garage
ELE07-01088 Conference11/15/200711/15/200711/15/2007 2:57:02 PMPDONE
shawn Phone #: ###-#### talked about disconnects, starters, strapping flex, clearances, fan coil installations
ELE07-01624 Electrical Rough-In11/15/200711/15/200711/15/2007 1:50:45 PMPPART
Scheduled by a contractor via Hello! on 11/15/2007 at 10:29:20 AM. Contact: ###-####. hard lids and dropped ceilings ok to cover anop
ELE07-03772 Rough-In Permanent Service11/15/200711/15/200711/15/2007 12:46:42 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ric ok, p/s u/g n ok
ELE07-03456 Conference11/15/200711/15/200711/15/2007 10:31:58 AMPDONE
leroy/david Phone #: ###-#### talked about electrical requirements for garage and items inspector looks for, grounding, cover, make-up, etc
ELE07-03645 Permanent Service11/14/200711/15/200711/15/2007 10:19:25 AMAPASS
greg Phone #: ###-#### p/s o/h rec ok
ELE07-02244 Electrical Rough-In11/14/200711/15/200711/15/2007 9:38:22 AMAPASS
Electrician is Shawn Evans. Rough and final. Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ric ok
ELE07-02244 Final11/15/200711/15/200711/15/2007 9:36:08 AMAPASS
Electrician is Shawn Evans. Rough and final. Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ok to final
ELE07-03825 Electrical Rough-In11/14/200711/15/200711/15/2007 9:35:02 AMAPASS
CALL SCOTT PRIOR TO HEADING TO SITE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy u/g ok to cover columns to gondolas - 2 places
ELE07-01405 Electrical Rough-In11/14/200711/15/200711/15/2007 8:54:23 AMAPART
shawn Phone #: ###-#### ok to cover u/g house to garage only, house needs 1 1/4" all over, make-up, circuiting for kitchen and bedrooms