ELE07-02763
| ELE-Aging Inspection | 11/15/2007 | 11/15/2007 | 11/16/2007 10:21:57 AM | | DONE |
|
|
called ,left message to call for inspection
|
ELE07-03252
| Electrical Rough-In | 11/15/2007 | 11/15/2007 | 11/15/2007 4:52:41 PM | P | FAIL |
|
|
chewey Phone #: ###-#### met owner, reviewed following: left correction notice,NEC 110.11 there shall be no agents that will deteriorate conductors, 250.86 shall ground metal boxes with approved means, 300.14 shall provide 6" free conductor length in boxes, 110.12(C) there shall be no broken boxes, 210.52(A)(1) no point along floor line shall be over 6' from a receptacle, 210.52(A)(2) wall space is 2' along floor line and shall have receptacle installed, 314.17(C) nm cable shall be stapled within 8" of 2x4 box, 210.12(B) bedrooms shall have listed arc fault circuit interrupters installed, 210.52(C)(1) countertops shall have receptacles installed within 2' of sink edge
|
ELE07-03614
| Electrical Rough-In | 11/14/2007 | 11/15/2007 | 11/15/2007 3:42:40 PM | P | PASS |
|
|
harry Phone #: ###-#### ok to cover u/g house to garage
|
ELE07-01088
| Conference | 11/15/2007 | 11/15/2007 | 11/15/2007 2:57:02 PM | P | DONE |
|
|
shawn Phone #: ###-#### talked about disconnects, starters, strapping flex, clearances, fan coil installations
|
ELE07-01624
| Electrical Rough-In | 11/15/2007 | 11/15/2007 | 11/15/2007 1:50:45 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 11/15/2007 at 10:29:20 AM. Contact: ###-####. hard lids and dropped ceilings ok to cover anop
|
ELE07-03772
| Rough-In Permanent Service | 11/15/2007 | 11/15/2007 | 11/15/2007 12:46:42 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ric ok, p/s u/g n ok
|
ELE07-03456
| Conference | 11/15/2007 | 11/15/2007 | 11/15/2007 10:31:58 AM | P | DONE |
|
|
leroy/david Phone #: ###-#### talked about electrical requirements for garage and items inspector looks for, grounding, cover, make-up, etc
|
ELE07-03645
| Permanent Service | 11/14/2007 | 11/15/2007 | 11/15/2007 10:19:25 AM | A | PASS |
|
|
greg Phone #: ###-#### p/s o/h rec ok
|
ELE07-02244
| Electrical Rough-In | 11/14/2007 | 11/15/2007 | 11/15/2007 9:38:22 AM | A | PASS |
|
|
Electrician is Shawn Evans. Rough and final. Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ric ok
|
ELE07-02244
| Final | 11/15/2007 | 11/15/2007 | 11/15/2007 9:36:08 AM | A | PASS |
|
|
Electrician is Shawn Evans. Rough and final. Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ok to final
|
ELE07-03825
| Electrical Rough-In | 11/14/2007 | 11/15/2007 | 11/15/2007 9:35:02 AM | A | PASS |
|
|
CALL SCOTT PRIOR TO HEADING TO SITE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy u/g ok to cover columns to gondolas - 2 places
|
ELE07-01405
| Electrical Rough-In | 11/14/2007 | 11/15/2007 | 11/15/2007 8:54:23 AM | A | PART |
|
|
shawn Phone #: ###-#### ok to cover u/g house to garage only, house needs 1 1/4" all over, make-up, circuiting for kitchen and bedrooms
|