Inspections for the day of: Tuesday, November 15, 2016.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-03709 Final11/15/201611/15/201611/15/2016 3:02:14 PMPCANC
Dennis Phone #: ###-####
needed p/s
ELE16-03709 Permanent Service11/15/201611/15/201611/15/2016 2:58:50 PMPPASS
Dennis Phone #: ###-####
p/s o/h rec ok
ELE16-02260 Electrical Rough-In11/15/201611/15/201611/15/2016 1:05:03 PMPPASS
Lee Phone #: ###-####
Under conveyor areas ok cover
ELE16-03657 Permanent Service11/15/201611/15/201611/15/2016 12:30:04 PMPPASS
Re-inspection. Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard
Corrections fixed ok to energize panel(homeowner did say he would pull a permit to do electrical on detached garage
ELE16-03705 Final11/14/201611/15/201611/15/2016 12:28:46 PMPCANC
would like call ahead; Paul Phone #: ###-####
Needed conference
ELE16-03705 Conference11/15/201611/15/201611/15/2016 12:28:36 PMPDONE
would like call ahead; Paul Phone #: ###-####
Discussed redoing service, there is no disconnecting means on exterior of building all unfused going to house panel. Homeowner will replace with a meter main ,upgrade groung electrode system, will seperate grounds and neutrals. Metal conduit will remain and existing feeders, will use ground bushing at both ends for equipment grounding to panel.
ELE16-03572 Electrical Rough-In11/15/201611/15/201611/15/2016 10:08:05 AMAFAIL
Inspect underground conduit for cover Phone #: ###-#### Inspection requested via web by Robert Schroder
352.24 Bends shall ne made so it will not damage internal radius
Shall not scorch outer coating of PVC
ELE16-03573 Electrical Rough-In11/15/201611/15/201611/15/2016 10:05:17 AMAFAIL
Inspect underground conduit for cover Phone #: ###-#### Inspection requested via web by Robert Schroder
352.24 Bends shall be made that will not damage internal raduis of conduit
Shall not scorch outer coating of PVC
ELE16-03574 Electrical Rough-In11/15/201611/15/201611/15/2016 10:03:32 AMAPASS
Inspect underground conduit for cover Phone #: ###-#### Inspection requested via web by Robert Schroder
Underground to shop ok cover
ELE16-02953 Final11/15/201611/15/201611/15/2016 9:31:23 AMAFAIL
Please call if you have any questions. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman
314.23 Boxes shall be rigidly mounted(w/p)
422.30 Shall provide disconnecting means for fixed appliances(dishwasher)
ELE16-03707 Permanent Service11/14/201611/15/201611/15/2016 9:04:04 AMAPASS
Need inspection for service change. Phone #: ###-#### Inspection requested via web by Alan Lusk
p/s u/g n ok Will remove type NM cable from exterior conduits
ELE16-03386 Final11/14/201611/15/201611/15/2016 8:38:24 AMAPASS
The 6bay garage is ready for a final insp, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren
Final for detached garages ok