Inspections for the day of: Tuesday, November 15, 2016.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS16-00032 MIS-Aging Inspection11/15/201611/15/201611/16/2016 9:19:44 AM DEFR
MIS16-00190 MIS-Aging Inspection11/15/201611/15/201611/16/2016 9:17:56 AM PASS
BLD16-03700 BLD-Conference11/14/201611/15/201611/15/2016 4:46:46 PMPCANC
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
BLD16-03700 BLD-Framing/Rough-in11/14/201611/15/201611/15/2016 4:38:11 PMPNR
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Needs plumbing rough in inspection.
ESC16-01402 Site Preparation11/15/201611/15/201611/15/2016 3:56:51 PMPPASS
BLD16-03771 BLD-Footing11/14/201611/15/201611/15/2016 3:56:28 PMPPASS
Dane Phone #: ###-####
ESC16-01283 Site Preparation11/15/201611/15/201611/15/2016 3:35:57 PMPPASS
BLD16-03401 BLD-Footing11/14/201611/15/201611/15/2016 3:35:45 PMPPASS
Dane Phone #: ###-####
BLD16-02948 BLD-Footing11/15/201611/15/201611/15/2016 2:53:58 PMPPART
Jason Phone #: ###-####. Work in progress. Will have special inspection.
BLD15-04514 BLD-Final11/15/201611/15/201611/15/2016 2:14:47 PMPPASS
John Phone #: ###-####. Ok for perm occ.
BLD16-01288 BLD-Final11/15/201611/15/201611/15/2016 2:02:38 PMPFAIL
Call half hour before to meet // Ferris Phone #: ###-####. 20 minute door to be selg closing, handrails need to return back to wall.
BLD15-01393 BLD-Framing/Rough-in11/15/201611/15/201611/15/2016 1:48:29 PMPFAIL
Shell Framing Final Phone #: ###-#### Inspection requested via web by Mike McHargue. Complete all lateral bracing. Nail off 2ply B02 truss per the engineering. Provide additional studs underB03 truss, both ends. Provide squash blocks at A13 truss both ends. Install the simpson A34 on all trusses per detail 6 on S1.5. Need electrical rough in inspection and airseal pack on exterior walls. Correction notice was posted.
BLD16-03260 BLD-Final11/14/201611/15/201611/15/2016 11:09:07 AMAPEND
Devin Phone #: ###-####. Needs to mount vertical grab bar at correct location (exceeds the 41" max from rear wall). Also noted several pieces of machining equipment tha thas ben moved in and wired. Per scope of work, this is a vanilla shell permit only, and no occupancy is allowed under this permit. Noted to ESI super to either have the existing permit modifed or have new tenants submit plans for occupancy. Noted that nothing has been submitted thus far for occupancy. Will final this permit when new tenant has submitted plans to planning and zoning for review.
GCB15-00090 GCB-Ceiling Grid11/14/201611/15/201611/15/2016 10:08:34 AMAPASS
Chris ###-#### - requests call ahead. Grid ceiling, 2nd. floor apartment ok.
BLD16-03726 BLD-Conference11/11/201611/15/201611/15/2016 9:30:45 AMADONE
Phone #: ###-#### Inspection requested via web by Scott Smith
BLD16-03726 DOC - Permit Finaled11/15/201611/15/201611/15/2016 9:30:35 AMPPASS
All work appeared to be done in accordance with local codes and ordinances.
BLD16-03021 BLD-Framing/Rough-in11/14/201611/15/201611/15/2016 9:01:25 AMAPASS
Rudolph Phone #: ###-####
BLD16-03242 BLD-Conference11/15/201611/15/201611/15/2016 8:36:26 AMADONE
Phone #: ###-#### Inspection requested via web by Todd Landvatter. Discussed phased inspections for framing and UL listings for 1hr. room.