Inspections for the day of: Wednesday, November 15, 2017.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01337 Electrical Rough-In11/14/201711/15/201711/15/2017 3:01:21 PMPPART
We are requesting a rough-in inpsection for the 2nd floor rooms, stairwell 1 and we are also requesting a consult inspection for the roof for tomorrow afternoon. Our contact is Rick @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate
Stair 1 not ready, West of grid line 12 roof OK to wire below. Units 202 thru 218 rough in ok cover.
ELE16-03931 Electrical Rough-In11/15/201711/15/201711/15/2017 2:02:38 PMPPASS
Dropped lids in Elevator Lobbies 333, 433,533,633,733 Phone #: ###-#### Inspection requested via web by Cathy Duchek
Areas noted signed off in office drop lids. Rough in ok cover
ELE16-03932 Electrical Rough-In11/15/201711/15/201711/15/2017 1:58:32 PMPPASS
Thrash rooms dropped ceilings 338,438,538,638,738 Phone #: ###-#### Inspection requested via web by Cathy Duchek
Areas noted trash rooms drop lids signed off in office. Rough in ok cover
ELE17-02610 Final11/14/201711/15/201711/15/2017 12:51:31 PMAPASS
Garage code 0654E. Phone #: ###-#### Inspection requested via web by Alan Lusk
Final ok
ELE17-03822 Final11/13/201711/15/201711/15/2017 10:17:01 AMANH
Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON
No answer at door. Called, will recall
ELE17-03066 Electrical Rough-In11/14/201711/15/201711/15/2017 10:00:02 AMAPASS
We are requesting a above ceiling inspection for tomorrow morning. Our contact is Bryant @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate
Kitchen grid rough in ok cover
ELE17-02099 Electrical Rough-In11/14/201711/15/201711/15/2017 9:55:25 AMAPASS
Harlan Phone #: ###-####
Horizontal runs located at back of garage not covered and shall be covered for final. Rough in ok cover
ELE17-03791 Final11/14/201711/15/201711/15/2017 9:15:13 AMAFAIL
Phone #: ###-#### Inspection requested via web by Celinda Winters
250.142- Grounded conductor shall not be connected to non-current carrying metal parts on load side of service disconnecting means. Old disconnecting means under meter has equipment ground tapped off grounded conductor in this box.
ELE17-03791 Permanent Service11/14/201711/15/201711/15/2017 9:08:56 AMAPASS
New Service inspection Phone #: ###-#### Inspection requested via web by Celinda Winters p/s u/g rec ok
ELE17-03856 Electrical Rough-In11/14/201711/15/201711/15/2017 8:46:35 AMAPASS
Phone #: ###-#### Inspection requested via web by Ryan Wake
Phase 1 south end lounge, office, 2 exam walls rough in ok cover