Inspections for the day of: Thursday, November 15, 2018.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-01019 ELE-Aging Inspection11/15/201811/15/201811/15/2018 2:25:07 PM PASS
Called contractor asked they make contact with new owner of residence for access on final inspection
ELE18-02032 Final11/15/201811/15/201811/15/2018 1:49:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Jim Noll Final ok
ELE18-02372 Final11/14/201811/15/201811/15/2018 11:39:04 AMANH
Phone #: ###-#### Inspection requested via web by Zane Robertson
Owner said shee had to leave to catch flight and had asked to schedule Monday.. Shall schedule when owner available to allow entry to house.
ELE18-04367 Permanent Service11/14/201811/15/201811/15/2018 10:48:53 AMANR
Josh Phone #: ###-####
No work performed yet, needed conference to discuss future service change to 200 amp.
ELE18-04367 Conference11/15/201811/15/201811/15/2018 10:48:41 AMPDONE
Josh Phone #: ###-####
Discussed requirements for changing 100 amp service to 200 amp. Removing service on garage and subfeeding from house. Minimum work space, underground depth, overhead clearances, Service entrance conductor size, metal underground water pipe present so shall be included in grounding electrode system and suplemented by an additional grounding electrode. Pamphlet given.
ELE17-04217 Final11/14/201811/15/201811/15/2018 10:04:16 AMAPASS
Mitch Phone #: ###-#### Final ok
ELE18-04353 Final11/14/201811/15/201811/15/2018 9:33:45 AMANR
Contact Jake for Access at ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer
Must confirm access to disconnecting means and recessed can and wiring supported in future.
ELE18-04353 Electrical Rough-In11/14/201811/15/201811/15/2018 9:32:39 AMAPASS
Contact Jake for Access at ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer
Ceiling opened up to installed HVAC unit and recessed can hanging on wiring. Must call in final in future to ensure electrical reinstalled and supported and access provided for unit with access to disconnecting means. Ceiling rough in ok cover
ELE18-00435 Final11/14/201811/15/201811/15/2018 8:44:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Candi Bahem
Scope of work- Service and panels on west side, conduits up and over to east side, panels and transformer on east side. Interior lighting, exterior remained existing and was refed. Rack removed from in front of west panels. Equipment consists of big ass fan and gas fired unit in North west corner. Riser room walls have been removed and will be replaced with new covered by new permit, MC to east exit sign not included. Final ok