Inspections for the day of: Friday, November 15, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04324 Rough-in11/15/201911/15/201911/15/2019 4:06:17 PMPPART
Please contact Glen with any issues ###-#### Phone #: ###-#### Inspection requested via web by Yvonne Bowman
- partial R/I ok on exhaust and fresh air ducting through roof
- all mech work will be exposed and can be seen once installed
MEC19-05187 Rough-in11/15/201911/15/201911/15/2019 3:18:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- fireplace R/I ok
MEC19-05184 Final11/15/201911/15/201911/15/2019 3:18:33 PMPFAIL
Phamash Phone #: ###-####
- line set penetration needs sealed
- A/C service ports need locking caps installed
- furnace flue needs b vent installed where combustibles are closer than 6"
- coil secondary condensate needs a wet switch installed
-gas line needs sediment trap installed
- couldn't access crawl builder said crawl access will be available at next inspection to check condensate and line set support
MEC19-04497 Final11/12/201911/15/201911/15/2019 2:36:53 PMPPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 1:30 PM. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- 5lb flue ok
- final ok
MEC19-04855 Final11/15/201911/15/201911/15/2019 1:58:16 PMPFAIL
Gener ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- one RTU needs flue extension installed
- three furnaces need venting finished and installed per Man specs
MEC19-05186 Pressure Test11/15/201911/15/201911/15/2019 1:55:55 PMPFAIL
If there are any issues, can you call Tom at this number? Phone #: ###-#### Inspection requested via web by Nat Golden
- this house doesn't have a gas line installed. thinking address is wrong for this permit. Called Tom and left voice mail
MEC19-04626 Final11/15/201911/15/201911/15/2019 1:54:37 PMPPASS
If there are any issues, can you call Tom at this number? Phone #: ###-#### Inspection requested via web by Nat Golden
MEC19-03990 Rough-in11/13/201911/15/201911/15/2019 11:20:54 AMAFAIL
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- 1st floor ceiling cover not ready. Talked with contractor about items that need finished
MEC19-03035 Final11/14/201911/15/201911/15/2019 10:45:57 AMAPASS
Contact jasper with any questions
Phone #: ###-#### Inspection requested via web by Ted Dumont
- RTU final ok
MEC19-05142 Rough-in11/14/201911/15/201911/15/2019 10:21:21 AMAPASS
Phone #: ###-#### Inspection requested via web by RaChelle Frisbee
- hard lid R/I ok
MEC19-04780 Final11/13/201911/15/201911/15/2019 10:11:30 AMAFAIL
call ahead to Chris @ ###-#### to make sure he can be home for inspector entry. Phone #: ###-#### Inspection requested via web by Angie Maguire
- furnace combustion air pipe needs connect to furnace
- coil needs wet switch installed
- tankless water heater needs flue venting installed with primer and glue. right now the intake looks glued and the exhaust isn't glue at all.
MEC19-01757 Final11/14/201911/15/201911/15/2019 9:52:01 AMAPART
Phone #: ###-#### Inspection requested via web by RaChelle Frisbee
- need TAB report for final
MEC19-04754 Final11/13/201911/15/201911/15/2019 9:29:19 AMAFAIL
PLEASE CALL HOMEOWNER KERRY WHEN IN ROUTE- SHE WORKS NIGHTS AND ASKED IF YOU CAN COME OUT ANYTIME AFTER 930A- I ADVISED THAT WE COULDNT GUARANTEE THAT BUT WE COULD CERTAINLY ASK NICELY TO SEE IF THE INSPECTOR ASSIGNED CAN ACCOMMODATE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- furnace ac coil co ok
- need to see electrical permit
MEC19-02427 Conference11/14/201911/15/201911/15/2019 9:08:23 AMACANC
Please Call Kyle @ ###-#### 45 min prior to arrival so he can meet inspector on site.
Thank you. Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
MEC19-04412 Final11/14/201911/15/201911/15/2019 8:55:17 AMAPASS
Please call Dave with any questions @ ###-#### Phone #: ###-#### Inspection requested via web by Dave DeChambeau
- tab report ok
- final ok
MEC19-04806 Final11/14/201911/15/201911/15/2019 8:34:16 AMAPASS
Diffuser replacement inspection Phone #: ###-#### Inspection requested via web by RaChelle Frisbee
- final ok
MEC19-05101 Final11/14/201911/15/201911/15/2019 8:00:45 AMAPASS
Locking caps have been put on and line set has been supported. Call Brett if you have any questions ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon
- final ok
MEC19-01814 Mec-Aging Inspection11/15/201911/15/201911/15/2019 8:00:06 AM PASS
WIP