Inspections for the day of: Tuesday, November 16, 2004.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-02822 Final11/15/200411/16/200411/16/2004 12:00:00 AMAFAIL
jack we are all done with the house and need to final the house out. the homeowner will have the house unlocked and should be there.; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa cor. called isolate grds and neuts at sub gear in garage, bushings for #4 and larger, needs manufactures equip grd kit for disconnect switch in garage, do not mix cual in wirenut 11/16/2004 8:49:59 AM
ELE04-03271 Electrical Rough-In11/15/200411/16/200411/16/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/15/2004 at 11:17:01 AM. Contact: ###-####. u/g ok , 2 other locations they will remove floor boxes and concrete over 11/16/2004 11:11:18 AM
ELE04-03403 Final11/15/200411/16/200411/16/2004 12:00:00 AMACANC
John;Would like mid-morning around 11:00- Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner
ELE04-01713 Electrical Rough-In11/15/200411/16/200411/16/2004 12:00:00 AMAPART
Ceiling Rough-in on Elevator Lobbies - All 4 Floors; Phone #: ###-#### Internet Inspection Request from: Barry Kendall anop 11/16/2004 11:10:25 AM
ELE04-03545 Permanent Service11/15/200411/16/200411/16/2004 12:00:00 AMAPASS
Pat-Trench Inspection; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner ok p/s o/h new ok 11/16/2004 8:26:06 AM
ELE04-03387 Final11/15/200411/16/200411/16/2004 12:00:00 AMAPASS
Electrician Rodger ###-####; Phone #: ###-#### Internet Inspection Request from: Keri Pascoe ok 11/16/2004 9:33:51 AM
ELE04-03350 Electrical Rough-In11/15/200411/16/200411/16/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/15/2004 at 8:08:55 PM. Contact: ###-####. ok 11/16/2004 10:10:55 AM
ELE04-00825 Rough-In Permanent Service11/16/200411/16/200411/16/2004 12:00:00 AMPPART
Phone #: ###-#### Internet Inspection Request from: Monty Adkinson no cover electricl ok , but low voltage contractor has not made corrections yet 11/16/2004 3:01:33 PM
ELE04-01527 Final11/16/200411/16/200411/16/2004 12:00:00 AMPCANC
Allen; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner done by 336 11/16/2004 1:37:51 PM
ELE04-03524 Final11/16/200411/16/200411/16/2004 12:00:00 AMPPASS
Mitch; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok see added p/s 11/16/2004 2:25:41 PM
ELE04-03250 Electrical Rough-In11/16/200411/16/200411/16/2004 12:00:00 AMPPART
Jim; Phone #: ###-#### Internet Inspection Request from: Jan Rice u/g ok 11/16/2004 3:35:16 PM
ELE04-02742 Final11/16/200411/16/200411/16/2004 12:00:00 AMPFAIL
cHRIS; Phone #: ###-#### Internet Inspection Request from: Jan Rice inspection called in by owner, not contractor, needs outlet for wall space kit west wall, 20 amp laundry circuit and recept, cut backsplash to outside dimension of boxes and boxes shall be flush (kit.) 11/16/2004 1:37:15 PM
ELE04-03403 Final11/16/200411/16/200411/16/2004 12:00:00 AMPPART
jOHN; Phone #: ###-#### Internet Inspection Request from: Jan Rice t/o ok no card 11/16/2004 1:04:16 PM
ELE04-03610 Permanent Service11/16/200411/16/200411/16/2004 12:00:00 AMPFAIL
###-#### - jann Note: Garage only cor. posted met owner no violations to be retained original work in violation, no SMS for grds or bonding, 11/2" mast shall not support drop, seal KOs, isolate grds and neuts at sub panel, gfci fro garage recepts, grd recepts to boxes, use manufactures listed breakers only, needs 2 grd rods, #8 cable in 3/4 emt not rated for 50 amps furnace feed shall be #6 11/16/2004 4:03:05 PM
ELE04-03524 Permanent Service11/16/200411/16/200411/16/2004 12:00:00 AMPPASS
p/s o/h rec. ok