ELE04-02822
| Final | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | FAIL |
|
|
jack we are all done with the house and need to final the house out. the homeowner will have the house unlocked and should be there.; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa cor. called isolate grds and neuts at sub gear in garage, bushings for #4 and larger, needs manufactures equip grd kit for disconnect switch in garage, do not mix cual in wirenut 11/16/2004 8:49:59 AM
|
ELE04-03271
| Electrical Rough-In | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/15/2004 at 11:17:01 AM. Contact: ###-####. u/g ok , 2 other locations they will remove floor boxes and concrete over 11/16/2004 11:11:18 AM
|
ELE04-03403
| Final | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | CANC |
|
|
John;Would like mid-morning around 11:00- Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner
|
ELE04-01713
| Electrical Rough-In | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | PART |
|
|
Ceiling Rough-in on Elevator Lobbies - All 4 Floors; Phone #: ###-#### Internet Inspection Request from: Barry Kendall anop 11/16/2004 11:10:25 AM
|
ELE04-03545
| Permanent Service | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | PASS |
|
|
Pat-Trench Inspection; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner ok p/s o/h new ok 11/16/2004 8:26:06 AM
|
ELE04-03387
| Final | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | PASS |
|
|
Electrician Rodger ###-####; Phone #: ###-#### Internet Inspection Request from: Keri Pascoe ok 11/16/2004 9:33:51 AM
|
ELE04-03350
| Electrical Rough-In | 11/15/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/15/2004 at 8:08:55 PM. Contact: ###-####. ok 11/16/2004 10:10:55 AM
|
ELE04-00825
| Rough-In Permanent Service | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Monty Adkinson no cover electricl ok , but low voltage contractor has not made corrections yet 11/16/2004 3:01:33 PM
|
ELE04-01527
| Final | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | CANC |
|
|
Allen; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner done by 336 11/16/2004 1:37:51 PM
|
ELE04-03524
| Final | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | PASS |
|
|
Mitch; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok see added p/s 11/16/2004 2:25:41 PM
|
ELE04-03250
| Electrical Rough-In | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | PART |
|
|
Jim; Phone #: ###-#### Internet Inspection Request from: Jan Rice u/g ok 11/16/2004 3:35:16 PM
|
ELE04-02742
| Final | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | FAIL |
|
|
cHRIS; Phone #: ###-#### Internet Inspection Request from: Jan Rice inspection called in by owner, not contractor, needs outlet for wall space kit west wall, 20 amp laundry circuit and recept, cut backsplash to outside dimension of boxes and boxes shall be flush (kit.) 11/16/2004 1:37:15 PM
|
ELE04-03403
| Final | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | PART |
|
|
jOHN; Phone #: ###-#### Internet Inspection Request from: Jan Rice t/o ok no card 11/16/2004 1:04:16 PM
|
ELE04-03610
| Permanent Service | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | FAIL |
|
|
###-#### - jann Note: Garage only cor. posted met owner no violations to be retained original work in violation, no SMS for grds or bonding, 11/2" mast shall not support drop, seal KOs, isolate grds and neuts at sub panel, gfci fro garage recepts, grd recepts to boxes, use manufactures listed breakers only, needs 2 grd rods, #8 cable in 3/4 emt not rated for 50 amps furnace feed shall be #6 11/16/2004 4:03:05 PM
|
ELE04-03524
| Permanent Service | 11/16/2004 | 11/16/2004 | 11/16/2004 12:00:00 AM | P | PASS |
|
|
p/s o/h rec. ok
|