ELE12-02982
| Conference | 11/16/2016 | 11/16/2016 | 11/16/2016 2:13:44 PM | P | DONE |
|
|
RE-INSPECTION late AM if possible Thanks Rock Phone #: ###-#### Inspection requested via web by Tom Betty Discussed Annex building outdoor lighting. Wanted to know if temp occupancy ok with lights hung on unfinished walls and columns. All egress lighting once installed shall remain in place for an emergency situation. If lights can remain in place YES, if lights are removed for finish NO. Need Fence or barrier to keep public away from heat trace for grease tank
|
ELE12-02982
| Final | 11/16/2016 | 11/16/2016 | 11/16/2016 2:12:22 PM | A | PART |
|
|
RE-INSPECTION late AM if possible Thanks Rock Phone #: ###-#### Inspection requested via web by Tom Betty Must have a barrier, fence or enclosure around 277 volt heat tape for grease tank. Jump parking garage temp final ok
|
ELE16-03673
| Rough-In Permanent Service | 11/15/2016 | 11/16/2016 | 11/16/2016 10:34:50 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey BLD to check soffits. Contractor stated all is where it needs to be with other questions. Rough in ok cover p/s u/g n ok
|
ELE16-03703
| Electrical Rough-In | 11/15/2016 | 11/16/2016 | 11/16/2016 10:07:17 AM | A | PASS |
|
|
Tile floor heat rough inspection Phone #: ###-#### Inspection requested via web by Rowdy Monroe Floor heat master bath rough in ok cover
|
ELE16-03606
| Rough-In Permanent Service | 11/15/2016 | 11/16/2016 | 11/16/2016 9:16:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE16-03692
| Rough-In Permanent Service | 11/15/2016 | 11/16/2016 | 11/16/2016 9:15:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|