ELE12-01744
| ELE-Aging Inspection | 11/16/2017 | 11/16/2017 | 11/20/2017 10:37:21 AM | | FAIL |
|
|
No responce to notice
|
ELE17-02457
| Final | 11/16/2017 | 11/16/2017 | 11/16/2017 2:29:10 PM | P | NH |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Recall with access code
|
ELE17-00870
| Final | 11/16/2017 | 11/16/2017 | 11/16/2017 2:09:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Victor Kelley Final ok
|
ELE16-01382
| Final | 11/16/2017 | 11/16/2017 | 11/16/2017 12:07:57 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle sign final ok
|
ELE17-03847
| Final | 11/15/2017 | 11/16/2017 | 11/16/2017 12:06:13 PM | P | PASS |
|
|
Corrected issues as discussed with inspector. Please contact with any concerns. Lock box is #1516. Thank you Phone #: ###-#### Inspection requested via web by Cortney Hopper corrections made final ok
|
ELE17-03435
| Electrical Rough-In | 11/16/2017 | 11/16/2017 | 11/16/2017 11:39:53 AM | P | PASS |
|
|
Please inspect floor heat in master and down stairs bathroom. Please call me a half an hour before inspection to insure access. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Floor heat only ok to cover
|
ELE17-03863
| Permanent Service | 11/15/2017 | 11/16/2017 | 11/16/2017 11:20:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew White p/s o/h n ok
|
ELE17-03885
| Temporary Service | 11/16/2017 | 11/16/2017 | 11/16/2017 10:54:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
|
ELE16-03797
| Final | 11/15/2017 | 11/16/2017 | 11/16/2017 10:54:33 AM | A | FAIL |
|
|
james Phone #: ###-#### 110.3 Reverse polarity on Recep. to Rt of fireplace. 210.8A7 Recep to right of Mudroom sink needs GFCI. 210.8A6 Kitchen counter receps need GFCI. 314.20 Kitchen Backsplash receps need Sparkrings. 352.30A Service riser needs stapped above slip joint. 356.30 A/C flex needs strapped within 12in of disconnect.422.30 Furnace needs disc. 110.24 36in x 36in platform needs constructed in front of meter.
|
ELE17-03666
| Permanent Service | 11/15/2017 | 11/16/2017 | 11/16/2017 8:44:53 AM | A | PASS |
|
|
Inspection for meter without power for more than 1 year Phone #: ###-#### Inspection requested via web by steve ragan p/s o/h rec ok
|
ELE16-02745
| Electrical Rough-In | 11/16/2017 | 11/16/2017 | 11/16/2017 12:00:00 AM | A | FAIL |
|
|
4th and fifth floor hallway grid 510-520 301-310 Phone #: ###-#### Inspection requested via web by Kenneth Chapman List of items with Fred/ Forman
|