Inspections for the day of: Thursday, November 17, 2005.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03040 ELE-Aging Inspection11/17/200511/17/200511/21/2005 9:51:41 AM FAIL
called cor. 600.5(C)(3),and 410.15(B)
ELE05-04182 Temporary Service11/17/200511/17/200511/17/2005 4:03:42 PMPPASS
bob-- ###-#### t/s o/h new ok
ELE05-03697 Electrical Rough-In11/16/200511/17/200511/17/2005 3:26:38 PMPNR
david/belina; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles need to meet owner too many things wrong ,and p/s was install in violation by prior owner, no violations to be retained called owner will schedule conference, box fill wall spacing, bath circuit has other outlets on it romex pulled in pvc, derate wires needs to update permit for 5 rms not 2
ELE05-03082 Permanent Service11/17/200511/17/200511/17/2005 2:22:46 PMPPASS
p/s u/g new ok for hook up and house meter
ELE05-04183 Final11/17/200511/17/200511/17/2005 1:25:02 PMPPASS
Jay ###-####///please call when on way so can meet you there ok cor. made
ELE05-04185 Electrical Rough-In11/17/200511/17/200511/17/2005 12:51:38 PMPPASS
###-#### - mike r/i
ELE05-04114 Temporary Service11/17/200511/17/200511/17/2005 12:09:21 PMPPASS
Scheduled by a contractor via Hello! on 11/17/2005 at 9:38:16 AM. Contact: ###-####. t/s u/g new ok
ELE03-00484 Final11/17/200511/17/200511/17/2005 11:03:54 AMAPASS
Scheduled by a contractor via Hello! on 11/17/2005 at 6:08:52 AM. Contact: ###-####. ok
ELE05-02764 Final11/16/200511/17/200511/17/2005 10:32:43 AMAPASS
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE05-04173 Final11/16/200511/17/200511/17/2005 10:04:04 AMAFAIL
Scheduled by a contractor via Hello! on 11/16/2005 at 1:18:35 PM. Contact: ###-####. called u/g not proper depth, 18" for pvc, 24" for uf
ELE05-04153 Temporary Service11/16/200511/17/200511/17/2005 9:40:32 AMAFAIL
Scheduled by a contractor via Hello! on 11/16/2005 at 1:22:45 PM. Contact: ###-####. cor. called 300.10 tighten all fitting and lugs, locknuts ,bond bushing, 312.5 conn for GEC, 110.12 clean t/s, 110.14 all strands of conductor grd wire under acorn clamp
ELE05-04124 Rough-In Permanent Service11/16/200511/17/200511/17/2005 9:37:58 AMAPASS
Scheduled by a contractor via Hello! on 11/16/2005 at 10:53:45 AM. Contact: ###-####. r/i ok p/s u/g new ok
ELE05-04134 Temporary Service11/16/200511/17/200511/17/2005 9:37:14 AMAPART
Re-inspection after corrections made. Contact is Perry.; Phone #: ###-#### Internet Inspection Request from: David Bonner needs to wire job shack
t/s o/h new ok for hook up
ELE05-04185 Permanent Service11/17/200511/17/200511/17/2005 12:00:00 AMPPASS
###-#### - mike p/s u/g rec. ok
ELE05-03082 Permanent Service11/17/200511/17/200511/17/2005 12:00:00 AMPPASS
meter pack inspection only, please; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney p/s u/g new ok and house meter